Validator 2000

Thermal validation solution for inspection of pharmaceutical, biotechnology and medical device manufacturing

This product is no longer sold. View active Product

Have questions? We're here to help!
Have questions? We're here to help!

For nearly two decades the Kaye Validator 2000 has been the standard for wired Validations systems in the Pharma/ Biotech industry. Thousands of users trust and rely on the accuracy, reliability and proven performance of the Validator 2000. With the introduction of the new Validator AVS, Kaye wants to ensure our large installed base of existing Validator 2000 users that, as we have done throughout our history, we continue to provide support and allow them ample time to properly plan for their future and provide uninterrupted validations.

Our support teams are providing flexible solutions for any customized requirements for users owning a Validator2000® unit, and supporting them through the transition to the Kaye Validator AVS.

• Intuitive study setup and extensive process calculations simplify valdiation process
• Improved data analysis, including ability to graph and report unlimited cycles and up to 25 groups
• Centralized network management of all passwords and audit trails
• Ability to merge data files from multiple Kaye Validator and ValProbe studies
• Sensor input modules minimize sensor handling and calibration, including 4/20 mA inputs
• Fully automated sensor calibration
• Operates standalone or with PC
• Enables compliance with FDA 21CFR Part 11 guidelines
• Total system accuracy, following guidelines for uncertainty measurement of 0.17°C (k=2)

Rejection69 db @ 60 Hz (12 inputs/sec)
Voltage Input0 to 10 VDC
Resolution1:72,000
Voltage Input30 days: ±(0.003% of reading + 2 counts + 4 microvolts)
Accuracy1 year: ±(0.006% of reading + 2 counts + 4 microvolts)
Sensivity0.5 microvolts/count on most sensitive range
Voltage Temp. Coef.±(0.1 microvolts + 0.001% reading)/°C
Compensator Temp Coef.±0.01°C per °C
Input Terminal Temperature Non-unformity0.1°C
Input Ranges-6 to 30mV, -60 to 300mV, -2 to 10V
EnvironmentalTemperature: 0 to 50°C (32 to 122°F)
Relative humidity: 95% non-condensing
Internal Memory2 Mb for data collection
Internal BatteryNiCad; 30 minutes of battery backup
Input Indepedance10KΩ. Source greater than 10KΩ produces open circuit indication
Common Mode160 db (8 inputs/sec) @ line frequency
Rejection145 db (12 inputs/sec) @ line frequency
140 db @ DC
Max. Common100V pk ch-to-ch
Mode Voltage350V pk ch-to ch to frame ground
Normal Mode82 db @ 60 Hz (8 inputs/sec)
Kaye Validator0.017°C
Resolution and short term stabilityK=1
IRTD Temperature Standard0.01°C
k=1
Temperature Reference0.051
K=1
Total System Uncertainty0.078°C
k=1
ThermocouplesType T, J, K: 0.1°C or F resolution; T limited range 0.01°C resolution
Scanning Speed8 or 12 inputs/sec at 50/60 Hz
Power90 to 250 VAC, 50/60 Hz
Fuse Rating2A Slo Blo
Size191 H x 343 W x 343 mm D (404 mm with SIM)
7.5 in H x 13.5 in W x 13.5 in D (15.9 in with SIM)
Weight9 kg (20 lbs)
Analog InputUp to 36

• Steam Sterilizers (Autoclaves)
• Dry Heat Sterilizers
• Steam in Place (SIP)
• Water Cascade/Fall Sterilizers
• Incubators
• Stability Chambers
• Freezers
• Freeze Dryer/Lyophilisation
• Vessel 

  • Thumbnail of document AAS BR 146 B Validator 022714 web 12394
    Download

    AAS BR 146 B Validator 022714 web 12394

    Download

Request a Calibration Quote

We’re here to make calibration easy. Request a quote today and let our team give you the care, precision, and service you can trust.
Learn more

Browse By Brands

Uncover the brands that set the standard for quality and dependability in every industry we serve.
Learn more