TTFM 6.1 Transit Time Flowmeter

Measures flow rate of relatively clean, non-aerated liquids

Starting at
$3,918.12USD
Have questions? We're here to help!
Have questions? We're here to help!
Configure
The TTFM 6.1 Transit-Time Flow Meter is ideal for treated clean water, raw water, cooling water, chemicals, hydraulic oil, low-conductivity water, water/glycol solutions, and diesel and fuel oils. The unit works by measuring the time-of-flight difference for ultrasonic sound pulses transmitted from one transducer to another. The time between transmitted and received signals is measured by the flow meter. Mount the TTFM 6.1 Transit-Time Flow Meter ultrasonic transducers on the outside of a pipe and use the built-in 5-button keypad to enter the pipe material, outer diameter, wall thickness, and fluid type. The TTFM 6.1 will display the correct transducer separation distance and mounting method.
 
With the TTFM 6.1 Transit-Time Flow Meter, you never need to be an expert in non-contacting flow measurement to get the best results in your application. Let us help you accurately measure the flow rate of relatively clean, non-aerated fluids in full pipes.
 
Easy to Choose
 
With only three easy-to-select transducer sizes that work on all common pipe materials and options tailored to fit your application, the TTFM 6.1 is the easiest choice to specify for your next clean-liquid flow application.
 
Easy to Use and Maintain
 
With interchangeable clamp-on transducers, standard mounting hardware, and a quick setup menu, installation is quick and shutdown-free. Perfect for both retrofits and new installations. With no moving parts, there is little to no maintenance required, and with solid-state components, there is no drift in performance over time, ensuring accuracy and peace of mind.
 
Easy Assistance Anywhere
 
With real-time sales and application support directly from Pulsar Measurement, world-class assistance is just a phone call away. For applications that require periodic recalibration, we're ready to support you with our cost-conscious calibration services and fast turnaround service.
 
Great things come in threes; the meter made to make your life easy.
• Three easy-to-select transducer options covering 15 mm to 1,200 mm nominal pipe diameters.
• Transducers work on all common pipe materials.
• Standard mounting hardware makes novice installers look like experts.
• Transducers don’t contact the pipe. There’s no wear and tear, and no shutdown to install.
• Easy-to-contact and knowledgeable staff is here to help you before, during, and after installation.
• Analog, pulse, and serial communication options to meet your specific application needs.
• Standard 26 million point data logger and free Logging Software make data management and reporting fast and easy.
• All transducers are approved for use in hazardous locations.
General Specifications
Spec:Description:
Operating ParametersFor clean liquids in full pipes with less than 2% solids or gas bubbles
ProgrammingBuilt-in, 5-button keypad with English, French, and Spanish menu language selection
Electronics EnclosureNEMA4X (IP 66) polycarbonate with clear, shatterproof cover
Accuracy±1% of reading from 0.5 m/s to 12.2 m/s (1.5 ft/s to 40 ft/s) and ±0.005 m/s (±0.015 ft/s) for velocity below 0.5 m/s (1.5 ft/s). Repeatability & Linearity: ±0.25%
DisplayWhite, backlit matrix - displays 5-digit flow rate with floating decimal, 14-digit totalizer, relay status, operating mode, and calibration menu
Power Input100-240 V AC 50/60 Hz, 10 VA maximum
Optional: 9-32 V DC, 10 W maximum
Analog OutputIsolated 4-20mA / 0-5 V, 1000 ohms load maximum, programmable offset
Control Relays2 Relays, form 'C' dry contacts rated 5 A SPDT; programmable flow alarm and/or flow proportional pulse
Optional: 4 additional (6 total), rated 5 A SPDT
Data LoggerBuilt-in 128 MB data logger with a USB output and Windows software. Capacity for approximately 26 million data points
Operating Temperature (Electronics)-20 °C to 60 °C (-5 °F to 140 °F)
Approximate Shipping Weight5.5 kg (12 lbs)
Sensor Specifications
Spec name:Description:
Pipe Diameter (Recommended)SE16A:  15 mm to 40 mm (0.5 in to 1.5 in)
SE16B:  50 mm to 250 mm (2 in to 10 in)
SE16C:  300 mm to 1,200 mm (12 in to 48 in)
Pipe Diameter(Suitable For)SE16A:  15 mm to 150 mm (0.5 in to 6 in)
SE16B:  50 mm to 1,200 mm (2 in to 48 in)
SE16C:  100 mm to 1,200 mm (4 in to 48 in)
Flow Velocity Range±0.02 m/s to 12.2 m/s (±0.07 ft/s to 40 ft/s)
Pipe MaterialsAny metal or plastic sonic conducting material including carbon steel, stainless steel, ductile iron, concrete-lined ductile iron, cast iron, PVC, HDPE, PVDF, fiberglass, copper, brass, aluminum, and pipes with bonded liners including epoxy, rubber, and Teflon
Operating FrequencySE16A:  2.56 MHz
SE16B:  1.28 MHz
SE16C:  640 kHz
Operating Temperature-40 °C to 150 °C (-40 °F to 300 °F)
Transducer Mounting KitSE16A:  Includes stainless steel track with pipe clamps and built-in ruler and coupling compound.
SE16B:  Includes a set of stainless steel pipe clamps, alignment bar, and coupling compound.
SE16C:  Includes set of stainless steel pipe clamps, alignment bar with a built-in ruler, and coupling compound
Transducer CablesTriaxial, 7.6 m (25 ft) with BNC connectors and seal jackets; extendable up to 152.4 m (500 ft)
Hazardous LocationsNon-incendive for Class I Div 2, Groups A, B, C, D
Optional: Intrinsically safe for Class I Div 1, Groups C, D

  • Thumbnail of document Ttfm 6 1 datasheet 14689
    Download

    Ttfm 6 1 datasheet 14689

    Download
  • Thumbnail of document Ttfm 6 1 instruction manual rev 2 1 14690
    Download

    Ttfm 6 1 instruction manual rev 2 1 14690

    Download

Accessories

Request a Service Quote

Get a customized quote for calibration, validation, repair, or training services designed to keep your instruments accurate and compliant.
Learn more

Browse By Brands

Uncover the brands that set the standard for quality and dependability in every industry we serve.
Learn more