 The two-wire input flex-hybrid transmitter TTB converts the temperature signal of the resistance thermometer into a scaled analog and digital signal (IO-Link and 4...20 mA) proportional to the temperature, whereby the two-wire loop is conducting both the power supply (voltage) and the output signal (current). The module directly can be mounted into the connecting head of the temperature sensor (e.g. TSB series). By mounting the transmitter directly at the point of measurement no additional converter in a cabinet system is necessary, this resulting in the advantages of low installation costs, uncomplicated wiring and high noise immunity.

• Installation into the sensor head (e.g. TSB) 
• Fully potted module 
• Connection directly to the PLC 
• Temperature linear 4...20 mA signal 
• Easy plug and play with IO-Link connectivity 
• Flex-hybrid technology   
    H: Transmitter with analog or IO-Link output
    D: Transmitter with analog or IO-Link output and display option 
• Easy exchangable 
• Transmitter in Polyamide housing
Temperature rangesambient: -40...85 °C (-40...185 °F)
(with Display): 0...70 °C (32...158 °F)
storage: -55...90 °C (-67...194 °F)
Measuring rangesstandard °C: -10...40, 0...50 / 100 / 150 / 200 / 250 °C
standard °F: 0...100 / 150 /200 / 250 / 300, 30...230 °F
custom ranges programable
Accuracyinput : ≤ 0.1 K (at ambient ≤ 85 °C (185 °F))
repeatability: ≤ 0.05 K
Temperature drifttypical: 5 mK/K (at 25 °C (77 °F))
maximum: 10 mK/K (at 25 °C (77 °F))
Adjustmentsdamping: 0...120 s
offset: ≤ ±10 K
slope: ≤ ±25 %
Digital outputIO-Link
digital resolution: 0.01 K
master cycle time: ≥ 51.2 ms
power supply: 18...30 V DC according to IO-Link
Analog outputSignal: 4...20 mA, 2 wire
accuracy: ≤ 0.05 % of upper range limit
temperature drift typical: 0.0005 %/K (at 25 °C (77 °F))
temperature drift max: 0.003 %/K (at 25 °C (77 °F))
effect of supply voltage: < 0.001 %/V (at 24 V DC)
variations:
maximum load resistance: R ≤ (V DC - 12 V) : 0.024 A (at 25 °C (77 °F))
power supply: 12...30 V DC