TRED30-16R 30 Day Display Temp. Logger W/ External Probe

Measures & stores up to 15,900 temperature readings over a -40°C to +99°C measurement range from an external probe

Starting at
$118.00USD
Have questions? We're here to help!
Have questions? We're here to help!
Configure

The LogTag® TRED30-16R Temperature Recorder measures and stores up to 15,900 temperature readings over a -40°C to +99°C (-40°F to +210°F) measurement range from an External Probe.

The display is designed to show ‘at a glance’ if temperature excursions have occurred during the current day and up to the previous 29 days. The display also shows the current temperature reading, the current time, recording status and battery status.

The alarm is trigged if temperature readings are outside pre-set alarm limits. The status indicator changes from a  to a X and, if configured, the audible alarm will sound. The day marker will also appear if not already present. The alarm status indicator and audible alarm can be easily cleared, but the day marker remains to ensure a visible record of excursions is shown on the display. A simplified alarm clearance, stop & start procedure is available as an option. Details of any excursions in the preceding 30 days can be checked directly by inspecting the statistics history on the recorder’s display or in more detail by downloading the logged data via a standard LogTag® Interface cradle to LogTag® Analyzer operating software.

• Built-in audible alarm.
• New, easy to read LCD display with 30 day summary in calendar format.
• Up to 15,900 recordings - Enough memory for 66 days at 6 minute logging.
• Auto-pause function - unplugging the external probe automatically suspends alarm & statistics processing.
• Record inspections at the push of a button.
• Interchangeable External Probe with high quality gold plated connector.
• Comprehensive customisation options including alarm settings, sample interval and trip duration

External Sensor Measurement Range-40°C to +99°C (-40°F to +210°F)
Operating Temperature Range-30°C to +60°C (-22°F to +140°F)
Storage Temperature Range-10°C to +40°C (14°F to +104°F)
Rated Temperature Reading AccuracyBetter than ±0.5°C (±0.9°F) for -20°C to +40°C (-4°F to +104°F), typically ±0.3°C (0.6°F).
Better than ±0.8°C (±1.4°F) for -40°C to -20°C (-40°F to -4°F), typically ±0.5°C (0.9°F)
Better than ±0.8°C (±1.4°F) for +40°C to +70°C (+104°F to +158°F), typically ±0.7°C (1.3°F)
Better than ±1.2°C (±2.2°F) for +70°C to +99°C (+158°F to +210°F), typically ±1°C (1.8°F)
Rated Temperature Reading Resolution 0.1°C (0.2°F) for measurements -40°C to +50°C (-40°F to +122°F)
0.2°C (0.4°F) for measurements +50°C to +70°C (+122°F to +158°F)
0.3°C (0.5°F) for measurements +70°C to +80°C (+158°F to +176°F)
0.4°C-0.6°C (0.7°F to 1°F) for measurements +80°C to +99°C (+176°F to +210°F)
Sensor Reaction TimeTypically less than 2 minutes (T90) in moving air (1m/s) for ST100T, ST100H and ST100S types
Recording Capacity15,905 temperature readings. 66 days @ 6min logging
Day summary statistics memory (for display on LCD): up for 30 days of Max/Min/duration and alarm trigger statistics
Sampling IntervalConfigurable from 30 seconds to hourly
Logging Start OptionsPush button start or specific date & time. Optional start delay of up to 18 hours
Recording IndicationState indicator “RECORDING"
Download TimeTypically less than 10 seconds for full memory (15,905 readings), depending on computer or readout device used
EnvironmentalIP61 (when vertically mounted or hung)
Power Source3V CR2032 (LiMnO2) coin cell battery, user replaceable
Battery LifeTypically 1 year of operation
NOTE: Typical battery life assumes 6 minute logging day statistics are reviewed on the display no more than once daily for no longer than 30 seconds each time.
Download data monthly
NOTE: Continual activation of the audible alarm will reduce the working life of the battery.When an alarm is triggered, the alarm should be cleared and reset as soon as possible
Real Time ClockBuilt-in real time clock
Rated accuracy ±25ppm @ 25°C (equivalent to 2.5 seconds/day)
Rated temperature coefficient is -0.034 ±0.006ppm/°C (I.e typically +/- 0.00294 seconds/day/°C)
Standard Remote Sensor Cable LengthStandard: 1.5m (4'11")
Extended: 3m (9'10") (Recommended maximum)
Remote Sensor Cable TypePTFE (FDA food contact rated), coaxial
Size93mm(H) x 54.5mm(W) x 8.6mm(T)
Weight41g
Case MaterialPolycarbonate
  • Thumbnail of document Log Tag TRED30 16 R Data Sheet 11212
    Download

    Log Tag TRED30 16 R Data Sheet 11212

    Download
  • Thumbnail of document TRED30 16 R Product Manual 11214
    Download

    TRED30 16 R Product Manual 11214

    Download

Request a Service Quote

Get a customized quote for calibration, validation, repair, or training services designed to keep your instruments accurate and compliant.
Learn more

Browse By Brands

Uncover the brands that set the standard for quality and dependability in every industry we serve.
Learn more