 Linearized and isolated RTD and Thermocouple transmitters are part of the Series SC4000 Iso Verter® II Signal Conditioning Modules. These modules completely isolate the input from the output and from the ground. Compatible with industry standard 35 mm DIN Rail mount transmitters and isolators, these modules are easily applied in new or existing installations.

 
The SC4380 Process Signal Converter/Isolator accepts virtually all standard process signals as input, and isolates and retransmits the signal in either the same units or virtually any other standard process signal. The SC4380 can be field programmed for reverse or direct action and can receive and transmit single sided or bipolar* signals. Low voltage units (SCL) are also available.
 
The SC4151 RTD Transmitters each offer a fixed scale range input (selected when ordered) and a linearized, isolated, field selectable 4 to 20 mA or 0 to 10 VDC output. Output is selected by simple switch settings. Low voltage units (SCL) are also available.
 
SC4130 Thermocouple Transmitter offers a fixed scale range input (selected when ordered) and a linearized, isolated, field selectable 4 to 20 mA or 0 to 10 VDC output. Output is selected by simple switch settings. Low voltage units (SCL) are also available.
 
*Note: The term "bipolar" refers to an input or output that crosses zero volts. Certain devices have ranges that run from minus to plus voltages ( e.g. -1 to +5 VDC, -10 to +10 VDC, etc.). The SC4380 Iso Verter® II can be set up to accept bipolar signal input or provide bipolar output.
• Up to 1500 VAC RMS electrical isolation
• Easily installed on industry standard 35 mm DIN rail
• Low voltage SCL units also available
Isolation1500 VAC RMS.
Linearity0.1% of full scale.
Drift±0.02%/°C typical, ±0.05%/°C maximum.
Power SupplySC: 85 to 265 VDC/VAC 50 to 400 Hz; SCL: 12 to 24 VDC/VAC 50 to 400 Hz.
Output LoadsCurrent: 600 Ω maximum Voltage: 500 Ω minimum (20 mA maximum).
Input CharacteristicsSC4380: Voltage: 1 MΩ impedance, Current: 10 Ω; SC4151: RTD search current < 500 µA; SC4130: 3 MΩ impedance.
Case Size0.866" W (22.5 mm) x 2.950" H (75.0 mm) 3 3.880" D (98.5 mm).
MountingMounts on industry standard 35 mm DIN Rail (DIN EN50022-35).
• Signal conditioners used in panels for isolation
• Converting signals for boilers and control systems
  • Thumbnail of document SC4 cat 17655
    Download

    SC4 cat 17655

    Download
  • Thumbnail of document SC4130 SC4151 SCL4151 iom 17656
    Download

    SC4130 SC4151 SCL4151 iom 17656

    Download

Request a Service Quote

Get a customized quote for calibration, validation, repair, or training services designed to keep your instruments accurate and compliant.
Learn more

Browse By Brands

Uncover the brands that set the standard for quality and dependability in every industry we serve.
Learn more