The Amprobe SC-3500 4” Signal Clamp for AT-3500 attaches around a buried metallic pipe, cable, or wire to induce a transmitted signal into the feature for active location and tracing. It does not require direct contact with metal to transmit the signal and can transmit signal through insulation on wires and into cable and wire bundles, providing more accurate tracing than locating with just a receiver and transmitter. Accommodates conductors up to 4″ in diameter. Transmits a 33 kilohertz (kHz) frequency supplied by the T-3500 Transmitter (included in the AT-3500 kit).

R-3500 Dynamic response rangeRange 1: radio 120 dB
Range 2: power network 135 dB
Range 3: transmitter 120 dB
R-3500 Sensitivity at a depth of 1mRange 1: radio >20 μA
Range 2: power network >7 mA
Range 3: transmitter >5 μA
R-3500 Frequency rangesRange 1: radio 15 kHz to 23 kHz
Range 2: power network 50 Hz / 60 Hz; optionally 100 Hz (can be adjusted by Amprobe service personnel)
Range 3: transmitter 32.768 kHz
Transmitter frequencySingle, non-adjustable
Passive Tracing Frequencies50 / 60 Hz
Depth Measurement10 ft (3.05 m)
R-3500 temp. range in accordance with DIN EN 60068-1Operation -4 ˚F to 131 ˚F (-20 °C to +55 °C)
Storage -22 ˚F to 158 ˚F (-30 °C to +70 °C)
R-3500 Operating time40 hours (for intermittent use with alkaline batteries, 20 °C)
R-3500 Power supply10 x IEC R6 / AA cell / Mignon
R-3500 AccuracyRange 1: radio ±20 %
Range 2: power network ±20 %
Range 3: transmitter ±5 % (>5m (6-FT)), ±20 % (<5m (15-FT))
R-3500 Depth determinationDepth range 4 in … 16 ft (0.1 m … 5 m)
Resolution 0.33 ft (0.1 m)
T-3500 type of protection in accordance with EN 60529Dust and water protected IP 56
T-3500 Dimensions (W x H x D)10.2 x 10 x 5.5 in (260 x 255 x 140 mm)
T-3500 Weight3.75 lbs (1.7 kg)
T-3500 temp. range in accordance with DIN EN 60068-1Operation -4 ˚F to 131 ˚F (-20 °C to +55 °C)
Storage -22 ˚F to 158 ˚F (-30 °C to +70 °C)
T-3500 Operating time40 hours (for intermittent use with alkaline batteries, 20 °C)
T-3500 Power supply6 x IEC R20 / D cell / Mono
T-3500 Frequency32.768 kHz
T-3500 transmitted power0.1 W / 0.5 W (switchable)
R-3500 type of protection in accordance with EN 60529Dust and water protected IP 67 from the lower edge of the receiver up to the lower edge of the battery compartment, and IP 56 for all parts above this delineation.
R-3500 Dimensions (W x H x D)3.9 x 26 x 9.9 in (99 x 660 x 252 mm)
R-3500 Weight5.5 lbs (2.5 kg)
  • Thumbnail of document AT 3500 Underground Cable and Pipe Locator 12146
    Download

    AT 3500 Underground Cable and Pipe Locator 12146

    Download
  • Thumbnail of document AT 3500 Underground Wire Pipe Locator Manual 12147
    Download

    AT 3500 Underground Wire Pipe Locator Manual 12147

    Download

Request a Calibration Quote

We’re here to make calibration easy. Request a quote today and let our team give you the care, precision, and service you can trust.
Learn more

Browse By Brands

Uncover the brands that set the standard for quality and dependability in every industry we serve.
Learn more