Skip to main content
Press Enter
Kaye

RF ValProbe II Loggers

Simplified real time validation, wireless high accuracy measurement of temperature and humidity

Have questions? We're here to help!
Have questions? We're here to help!
Wireless High accuracy measurement of temperature and humidity
 
The Kaye RF ValProbe II wireless data logger integrates breakthrough RF Mesh technology with enhanced technology for Thermal Validation. The operating range of the loggers of -40°C to +60°C and temperature sensor range of -200°C to +200°C make them ideal for real-time RF validation and monitoring of environmental chambers, warehouses, freezers, refrigerators and steam-in-place (SIP) applications.
 
The RF ValProbe II wireless data logger system utilizes a 2.4 GHz RF Mesh network and multiple redundant data storage to provide ultra- reliable and robust communications and storage of critical validation data. Additional safeguards guarantee data integrity, storage and compliance with regulatory requirements. The RF ValProbe II wireless data logger system is comprised of RF wireless data loggers, a base station and software. The wireless data loggers provide high accuracy measurement of temperature, humidity, and any 4 to 20mA or 0 to 10V output.
RF ValProbe’s wireless data logger software enables support for 2-Channel and 5-Channel RF Temperature loggers for validation.
 
The RF ValProbe II wireless data logger software provides ease of use by incorporating features such as self-configuring of the mesh network and automatic data collection. Extensive graphing, reporting and calculation capabilities minimize data analysis and provide regulatory-compliant reports.
• RF Mesh Networking technology provides reliable real time process data. Uses global 2.4 GHz RF frequencies
• Provides 100% data redundancy in both remote logger and base station in addition highly reliable RF network
• New State of Art Industrial design with integrated LCD Display
• Dual powered, logger runs on AC Power and/or Battery. Battery life greater than 1 year in typical use, using Standard 3.6V AA Primary Lithium batteries 
• Additional options for redundancy data retrieval and backup using micro SD card and USB
• Emergency Battery backup for base station (30 min) for uninterrupted operation using 3.6V AA size Lithium rechargeable batteries
• Intuitive study set-up and extensive calculations Simplify the validation and reporting process
• Base Station connections for IRTD and Bath for Sensor Calibration or Verification
• Protective rubber boot with flexible stand for multiple monitoring configurations
• Best-in-class data analysis tools, including ability to graph and report in cycles and groups
• Report tool can process and create merged reports from RF ValProbe, ValProbe or Validator products
• Versions provide temperature to 0.1°C accuracy, RH to 2% RH, 4/20 mA, 0 to 10 V and dry contact switch inputs, 2-Channel and 5-Channel Temperature logger
• Up to 3 meter extension cable for RH sensor allows sensor to be placed inside the chamber and logger placed outside
• Temperature and pressure accuracy meets requirements for ISO-17665, EN554 and EN285 sterilization requirements
• Easy connection to Kaye Pressure transducer which is designed for harsh environment applications such as steam sterilizers and SIP systems
• Can be directly connected to 1.5 inch triclover flange via SmartGasket® or similar gasket design
 
Battery Life (Varies +10%)1 min sample rate: 1 Year
Auxiliary Inputs• Contact: Dry
• Voltage and current 0.5% FS
RH• ±2% from 25 to 85%RH
@ 25°C to 40°C (Non-condensing environment)
• Certificate states ICH Points
Single/Multi Channel External Sensor• ±0.1°C, range -50°C to +130°C
• ±0.2°C, range -80°C to -50°C
• -196°C to -80°C & +130°C to 200°C
Contact factory for accuracy
Temperature
Base Station Dimensions190 mm x 130 mm x 55 mm
(7.6 in x 5.2 in x 2.2 in)
Logger Dimensions110 mm x 65 mm x 30 mm
(4.3 in x2.6 in x 1.2 in)
External Probe-196°C to 200°C
Body (Base Station Enclosure)-40°C to 60°C (Storage)
0 to 90% RH non-condensing
0°C to 50°C (Operating)
0 to 90% RH non-condensing
Body (Logger Enclosure)-40°C to 60°C (Storage)
0 to 90% RH non-condensing
-25°C to 60°C (Operating)
0 to 90% RH non-condensing
Environmental

 The Kaye RF ValProbe II integrates breakthrough RF Mesh technology with enhanced technology thermal validation in situ loggers. The operating range of the loggers of -40°C to +60°C and temperature sensor range of -200°C to +200°C make them ideal for real-time RF validation and monitoring of

• Environmental Chambers
• Warehouses
• Freezers
• Refrigerators
• Steam-in-Place (SIP) 
  • Thumbnail of document Kaye RF Val Probe II manual 12045
    Download

    Kaye RF Val Probe II manual 12045

    Download
  • Thumbnail of document 220213 AAS BRK 06001 A LS RF Val Probe II 14919
    Download

    220213 AAS BRK 06001 A LS RF Val Probe II 14919

    Download

Request a Calibration Quote

We’re here to make calibration easy. Request a quote today and let our team give you the care, precision, and service you can trust.
Learn more

Browse By Brands

Uncover the brands that set the standard for quality and dependability in every industry we serve.
Learn more