The next generation Advanced Quartz Crystal Microbalance analyzer from Michell Instruments is designed to provide reliable, fast and accurate measurement of trace moisture content in a wide variety of process applications where keeping moisture levels as low as possible is of critical importance.

• Fast and reliable measurement from 0.1 to 2000ppmV
• Accuracy of ±0.1ppmv at <1ppmv and 10% of reading from 1 to 2000ppmv
• Maintenance-free for 3 years
• Built-in verification of customer process gas
• IECEx, ATEX, TC-TR Ex certified for Exd flameproof, CSAus certified for explosion proof
• Intuitive, color HMI with touch-screen keypad; no ‘hot work’ permit required
• 14 internal alarms
• 21 predefined carrier gases and 3 user-defined gases
• Proven Michell Instruments quality: 40 years of expertise in moisture measurement built into the design

Measuring TechnologyFast Response Quartz Crystal Microbalance
Calibrated Range*0.1 to 700ppmv
Measurement Range0.1 to 2000ppmv
Accuracy±10% of reading from 1 to 2000ppmv
±0.1ppmv between 0.1 & 1ppmv
Repeatability±5% of the reading from 1 to 2000ppmv
±0.1ppmv between 0.1 & 1ppmv
Limit of Detection0.1ppmv
Available Unitsppmv, ppmw, mg/Nm3, vapor pressure (Pa), dew point (°C/°F), lb/MMscf
Response SpeedT63 <2 mins to step change in either direction
T95 <5 mins to step change in either direction
Automatic CalibrationInternal moisture generator source calibrated traceable to NPL & NIST
Sensitivity0.01ppmv or 1% of reading, whichever is greater
Electrical Specifications
Supply Voltage 85 to 264 V AC, 47/63Hz or 24 V DC (ATEX / IECEx)
24 V DC only (CSAus)
Alarms1 x system alarm, volt-free change-over (FORM C) 3 x process alarms, selectable for various parameters, volt-free changeover (FORM C)
Analog Signals2 x 4–20 mA or 1–5 V (selectable)
Maximum load resistance 500 Ω for 4–20 mA and minimum load of 1M Ω for 1–5 V
Digital Communications RS485 ModBus RTU
Modbus TCP
Data LoggingAvailable on analyzer (Limited number of values)or via Application Software
Local Interface7” color LCD with intuitive HMI
Electrical ConnectionsM20 entries for cable glands
Operating Conditions
Inlet Pressure3 barg
Outlet Pressure2 barg
Sample Flow300ml/min total flow
Sample Gas Temperature0 to +100°C (+32 to +212°F)
Operating EnvironmentAnalyzer only +5 to +45°C (+41 to +113°F) up to 90% RH
Analyzer in sampling system –20 to +55°C (–4 to +131°F) up to 95% RH (fitted with heater/thermostat and/or enclosure cooling as appropriate to maintain +5 to +45°C (+41 to +113°F) internal temperature)
Mechanical Specifications
TypeGUB Flameproof Exd
Gas ConnectionsLid & body: Cast copper-free aluminum LM25 (EN AC-42000), less than 0.6 magnesium
Glass window: Heat resistant, explosion proof, polyester coated, IP66, NEMA 4
Weight35kg without sampling system
Sample System Enclosure316L stainless steel
Certifications
Hazardous Area CertificationATEX II 2 GD Ex d IIB+H2 T6 Gb, Ex tb IIIC T85°C Db, Tamb -40°C to +60°C
IECEx Ex d IIB+H2 T6 Gb, Ex tb IIIC T85°C Db, Tamb -40°C to +60°C
CSAc Class I, ZONES, Ex d IIB+H2 T6 Gb, Tamb -20°C to +55°C
CSAus Class I, Div 1, Group BCD T6, Tamb -25°C to +55°C
TC-TR 1Ex d IIB+H2 T4 Gb X, 1Ex tb IIIC 130°C Db X and 1Ex d IIB+H2 T3 Gb X, 1Ex tb IIIC 195°C Db X
  • Thumbnail of document QMA601 MON Data Sheet 9926
    Download

    QMA601 MON Data Sheet 9926

    Download
  • Thumbnail of document QMA601 MON Manual 9927
    Download

    QMA601 MON Manual 9927

    Download

Accessories

Request a Service Quote

Get a customized quote for calibration, validation, repair, or training services designed to keep your instruments accurate and compliant.
Learn more

Browse By Brands

Uncover the brands that set the standard for quality and dependability in every industry we serve.
Learn more