Skip to main content
Press Enter
OMEGA

PX653-10BD5V Bidirectional, Differential Low Press. Transmitters

-10 to 10 inH2O, 1 to 5 Vdc

Normally ships in
2-3 weeks
Have questions? We're here to help!
Have questions? We're here to help!

Supported Applications

The Omega PX653 series comprises bidirectional, differential low-pressure transducers designed for clean rooms, HVAC systems, and laboratory fume hoods. These devices utilize capacitance sensor technology to measure dry, clean, non-corrosive gases only.

Operating Conditions & Performance

The PX653 series operates within an ambient temperature range of -29 to 72°C (-20 to 160°F) with a compensated temperature span of 2 to 57°C (35 to 135°F). Measurement ranges extend from low-pressure differentials, including unidirectional spans such as 0 to 0.1 inH₂O (0 to 25 Pa) up to 0 to 50 inH₂O (0 to 12.5 kPa), and bidirectional spans ranging from ±0.1 inH₂O (±25 Pa) to ±50 inH₂O (±12.5 kPa). Performance specifications include an accuracy of 0.5% FS (BFSL), linearity of 0.5% FS (BFSL), hysteresis of 0.02% FS, and repeatability of 0.05% FS.

Thermal effects are specified as 0.015% FS/°F for zero shift and 0.015% rdg/°F for span shift. The response time is 250 ms. Pressure limits include a proof pressure of 15 psi, burst pressure of 20 psi, and static pressure rating of 25 psi.

Series Envelope

The broader PX653 family (including models PX654, PX655, and PX656) supports additional configurations. Models PX654 and PX656 feature a NEMA 4X enclosure with an operating temperature range of -20° to 185°F (-29° to 85°C). The series offers output options including 1-5 Vdc (3 wire) for voltage models and 4-20 mA (2 wire) for analog current models. Excitation requirements are consistent across the family at 12 to 36 Vdc.

Configuration Options

The series is configurable by measurement range, directionality, output signal type, and enclosure rating. Key selection parameters include:

• Measurement Ranges: Unidirectional (0 to X) or bidirectional (±X) in units of inH₂O and Pa/kPa.
• Output Signals: 1-5 Vdc (3 wire) for PX653/PX654 models; 4-20 mA (2 wire) for PX655/PX656 models.
• Enclosure Ratings: NEMA 2 (IP62) for indoor applications (PX653, PX655); NEMA 4X for harsher environments (PX654, PX656).
9 Process Connections: ¼ barbed fittings compatible with tubing TY-316-100; some variants offer 1/8 and 1/4 barbed or 1/4 NPTF connections.
• Electrical Connection: Screw terminal blocks, with conduit options (Two 1/2 NPTF) available on specific models.

All units include a NIST traceable calibration certificate. Compatible display meters such as the DP3002-E, DP25B-E, DP41-E, and DP460-E are listed for integration with various ranges.

Key Product Differences

The PX653 series is distinguished by model-specific enclosure ratings and output configurations. Models PX653 and PX655 utilize a NEMA 2 (IP62) enclosure, while models PX654 and PX656 are rated NEMA 4X. The voltage-output variants (PX653, PX654) provide a 1-5 Vdc signal with a supply current of less than 5 mA. Analog output variants (PX655, PX656) deliver a 2-wire 4-20 mA signal with a maximum loop resistance defined as (supply voltage -10) x 50 ohms.

Physical dimensions vary by enclosure type: the NEMA 2 models measure approximately 107 H x 117 W x 53 mm D (4.2 x 4.6 x 2.1 in), while the compact NEMA 4X housings differ in profile to accommodate environmental protection requirements.

• Clean Rooms
• HVAC
• Laboratory Fume Hoods
• NIST Traceable Calibration Certificate
Accuracy Class> 0.25%
Burst Pressure20 psi Maximum
Compensated Temperature, Max57 °C
Compensated Temperature, Min2 °C
Current Draw<5 mA
Electrical ConnectionScrew Terminal
Electrical Output Note1 to 5 Vdc (3 wire)
Enclosure RatingsIP62, NEMA Type 2
Gauge TypeCapacitance
Hysteresis0.02% FS
Length53 mm
Line/Static Pressure25 psi
Linearity Error0,005
Operating Temperature, Max72 °C
Operating Temperature, Min-29 °C
Measurement Pressure TypeDifferential
Process Connection Note1 ⁄4 barbed fittings (tubing TY-316-100)
Process Connection Size1/4 in
Proof PressureUp to 15 psi
Repeatability Error0.05% FS
Response Time250 ms
Series IDPX653
Shunt Calibration ValueNIST cal at 25, 50, 75 and 100% FS; upscale and downscale provided
Supply Voltage12 to 36 Vdc
Thermal Effect on Zero error, Max0.015% rdg/°F , 0.015% FS/°F
Weight368 g
Width117 mm

Request a Calibration Quote

We’re here to make calibration easy. Request a quote today and let our team give you the care, precision, and service you can trust.
Learn more

Browse By Brands

Uncover the brands that set the standard for quality and dependability in every industry we serve.
Learn more