PX3005-160WDWBI Rangeable, Differential Press. Transmitters w/Display
-160 to 160 inH2O, Differential Pressure
Supported Applications
The Omega PX3005-DIFF is a rangeable differential pressure transmitter designed for process automation, hydraulic systems, compressors, pumps, and tank level applications. The series utilizes an encapsulated MEMS piezoresistive sensor coupled with advanced microprocessing to monitor pressures in environments requiring consistent measurement of fluids and gases compatible with 316 SS.
Operating Conditions & Performance
The PX3005-DIFF operates within a process temperature range of -40 to 120°C (-40 to 250°F) and an ambient operating temperature of -20 to 70°C (-4 to 160°F). Storage is supported from -40 to 85°C. The transmitter features a rugged 316 SS enclosure with an IP67 environmental rating, suitable for wash-down environments.
Performance specifications include an accuracy of ±0.075TD% SPAN (NLHR, 20°C ±5°C) for linear output; square root output accuracy is 1.5 times the linear output accuracy. Long-term stability is rated at ±0.2% URL/60 months. The sensor response time is 200 mS with selectable damping from 0 to 100 S.
Static pressure limits are defined by range: for ranges up to 400 Mbar, the limit is 400 Bar; specific over-range limits vary by model. The series supports a power supply of 10.5 to 55VDC with a load resistance calculated as <(U-10.5)/0.021 Ω.
Measurement Ranges
The documented differential pressure ranges include:
• -25 to 25 inH2O (PX3005-25WDWBI)
• -160 to 160 inH2O (PX3005-160WDWBI)
• -1,000 to 1,000 inH2O (PX3005-1KWDWBI)
• -70 to 150 psi (PX3005-150DWBI)
• -70 to 400 psi (PX3005-400DWBI)
• -70 to 1,500 psi (PX3005-1.5KDWBI)
Rangeability allows adjustment of zero and span from -100 to 100% FS URL with a minimum span of 30% URL.
Configuration Options
The series offers configurable output signals, display options, and process connections tailored to specific installation needs. The intelligent transmitter module supports configuration via a 5-digit backlit LCD for full precision representation of the process variable.
Outputs & Signals
• Output Signal: 4 to 20mA Two wire, linear or square root output selectable.
• Electrical Connection: 4 pin male M12 connector (wiring: Brown/Power+, White/Signal+, Blue/Signal-, Black/Power-).
Housing & Materials
• Housing Material: 316 SS.
• Isolating Diaphragm: 316L SS.
• Sensor Fill Fluid: Silicone Oil.
• Sensor Seal: O-ring, FKM.
Process Connections & Mounting
• Standard Connection: ¼" -18NPT F/316 SS.
• Mounting Options: The series supports bracket installation options including pipe mounting bent, plate mounting bent, and pipe mounting flat configurations (per family manual).
Key Product Differences
The PX3005-DIFF series is distinguished by its specific pressure ranges and model numbering. The available variants cover low differential pressures in inches of water column (-25 to 1,000 inH2O) and higher differential pressures in psi (-70 to 1,500 psi). All listed models feature the "DWBI" suffix indicating a display module with specific wiring configurations.
Technical distinctions include:
• PX3005-25WDWBI: -25 to 25 inH2O differential range.
• PX3005-160WDWBI: -160 to 160 inH2O differential range.
• PX3005-1KWDWBI: -1,000 to 1,000 inH2O differential range.
• PX3005-150DWBI: -70 to 150 psi differential range.
• PX3005-400DWBI: -70 to 400 psi differential range.
• PX3005-1.5KDWBI: -70 to 1,500 psi differential range.
| Accuracy | ± 0.075 % |
| Accuracy Class | < 0.1% |
| Accuracy Detail | Accuracy (NLHR, 20°C ± 5°C): ± 0.075TD% SPAN (Square root output accuracy is 1.5 times linear output accuracy) |
| Additional Features 1 | Rangable with 5 digit display |
| Damping Time | 0 to 100 sec |
| Electrical Connection | M12 4 pin |
| Electrical Output | 4 to 20 mA |
| Electrical Output Note | 4 to 20mA Two wire, linear or square root output selectable |
| Enclosure Material | 316L Stainless Steel |
| Enclosure Ratings | IP67 |
| Fill Fluid | Silicon oil |
| Loop Resistance, Max | <(U-10.5)/0.021Ω, where U is supply voltage |
| Operating Temperature, Max | 70 °C |
| Operating Temperature, Min | -20 °C |
| Output Signal | Current |
| Position Effect | Install error less than 400Pa (1.60” H2O) can be corrected by PV = 0 reset |
| Power Supply | 500 mW |
| Measurement Pressure Type | Differential |
| Process Connection Size | 1/4 in |
| Process Connection Type | NPT Female |
| Process Temperature, Max | 120 °C |
| Process Temperature, Min | -40 °C |
| Response Time | 200 ms |
| Series ID | PX3005-DIFF |
| Stability | ± 0.2% |
| Stability Note | ± 0.2% 60 months |
| Storage Temperature, Max | 85 °C |
| Storage Temperature, Min | -40 °C |
| Supply Voltage | 10.5 to 55 Vdc |
| Thermal Effect on Zero error, Max | ± (0.1 +0.1TD)% SPAN |
| Transmission Distance | up to 1000 meters |
| Vibration Effect | GB/T 1827.3/IEC61298-3 tests, 20g (5 to 2000 HZ, max <± 3 mm), <0.1% URL |
| Weight | 3 kg |
OMEGAM12-S-F-FM Field mountable M12 & M8 Connectors
Field Mountable M8 and M12 Connectors
Call Today!
800-567-8686Normally ships in 2-3 weeks
OMEGAM12C-PVC-4-R-F-5 M12 Cable, 4pin, for Transmitters, RTD, Thermistor
DC Cable Assemblies for Probes, Sensors and Transmitters
Call Today!
800-567-8686Normally ships in 2-3 weeks
OMEGAM12C-PUR-4-S-F-10 M12 Cable, 4 pin
DC Cable Assemblies for Probes, Sensors and Transmitters
This product is no longer available. Contact us at 800-567-8686 for alternative solutions.
OMEGAM12-R-F-FM Field Mountable M12 & M8 Connectors
Field Mountable M8 and M12 Connectors
Call Today!
800-567-8686Normally ships in 2-3 weeks
OMEGAM12C-SIL-4-S-F-5 M12 Cable, 4 pin, for Transmitters, RTD, Thermistor
DC Cable Assemblies for Probes, Sensors and Transmitters
Call Today!
800-567-8686Normally ships in 2-3 weeks