PRL True Echo Pulse Radar Level Transmitter

Provides accurate level readings from all types of liquid level measurement materials, IP68 for worry-free operation, ranges to 50 or 100 feet with ±0.25% accuracy

Starting at
$3,149.36USD
Have questions? We're here to help!
Have questions? We're here to help!
Configure

The True Echo™ PRL brings the unassailably accurate level readings of radar sensors to all types of liquid measurement.

Versatile Materials
Two housing materials plus multiple antenna choices equals a sensor that operates anywhere you need it to.

Easy Wiring & Set-up From an isolated 4-20 mA output, to push-button field calibration, everything about the True Echo™ PRL is easy.

Oil-Water Interface Detector A firmware addition adds Oil-Water Interface detection to the True Echo™ PRL's already versatile capabilities.

• Ranges to 17, 50, or 100 feet
• ±0.25% of measured range accuracy
• 6.1 μA output resolution
• Field configurable 4-20 mA/20-4 mA Output
• RS-232, RS-485, or HART communications
• PC calibration, diagnostic and data logging software
• PLC compatible (Modbus RTU)
• Nema 6/ IP68 enclosure rating
• Simple installation and setup
• Automatic adjustments for most tank conditions
• Very low material dielectric constant requirement
• Low Dielectric Material mode for ε < 4
• Firmware addition for Oil-Water Interface measurement
• Optional Fast Firmware for quickly changing levels
 

Operating RangePRL-017: 1 -17 ft. (0.3 - 5 m)
PRL-050: 1 - 50 ft. (0.3 - 15 m)
PRL-100: 1 - 100 ft. (0.3 - 30 m)
Frequency6.3 GHz
Accuracy± 0.25% of measured range
4-20 mA Resolution6.1 μA (approx. 2622 digital counts across range)
Target Dielectric Constantεr > 2
Environmental
Enclosure Operating Temperature-40º to 140ºF (-40 to 60ºC)
Process/Probe TemperaturesStandard -40º to 176ºF (-40 to 80ºC)
High Temp -40º to 350ºF (-40 to 177ºC)
Sanitary -40º to 400ºF (-40 to 204ºC)
Extreme Temp -40º to 572ºF (-40 to 300ºC)
Maximum Process PressuresStandard Temp/Pressure 5 bar (72.5 psi)
Standard Temp/High Press 70 bar (1015.3 psi)
High/Sanitary/Extreme Temps 2 bar (29.0 psi)
EnclosureNEMA 6: Aluminum or 316L Stainless Steel, IP68 Sealing
Electrical
Loop ResistanceRL = (VS- 6) / 24 mA
Input Voltage12-30 VDC; 20-35 VDC (HART);
115 VAC (60 Hz); 230 VAC (50 Hz)
Power Consuption0.07 A max, 1.68 W @ 24 VDC
1.7 VA for 115/230 VAC
Connectivity
Output4-20 mA (shared common or isolated); HART 7
ProgrammingRS-485, RS-232, or HART for calibration and diagnostics
Physical
AntennaRod: Teflon, 10.3” (261.6 mm)
Beam Spread: 6° from center
Horn: 316L Stainless Steel, Ø 6.3” (160 mm)
Beam spread: 3° from center
CertificationFCC - Part 15 for low power communications class II install

Accessories