Skip to main content
Press Enter
Greyline Instruments by Pulsar

PDFM 5.1 Portable Doppler Flow Meter

Doppler flow meter for troubleshooting, balancing & checking performance of permanent flow meters, recommended for difficult liquids

This product is no longer sold. View active Product

Have questions? We're here to help!
Have questions? We're here to help!
The PDFM 5.1 Portable Doppler Flow Meter is a portable flow meter that clamps to the outside of a pipe to gain pipe flow measurement. The ultrasonic Doppler technology used by the PDFM 5.1 makes it perfect for use as a water flow meter, specifically for dirty or difficult liquids that contain bubbles or solids, like wastewater, slurries, sludge, chemicals, viscous liquids, and abrasives.
 
The PDFM 5.1 is ideal for evaluating system performance and can be installed, calibrated, and started up in minutes. Use this flow meter where a permanent flow meter is not required, or temporarily replace installed flow meters. Fast and easy to operate, the sensor mounts to the outside of a pipe in less than a minute, using the built-in keypad and calibration menu to set up the flowmeter for the application.   
 
With its internal battery, the PDFM 5.1 will operate all day and recharge overnight. For continuous use, it can be powered by a supplied 110-240 V AC wall plug adaptor or use Sleep Mode to only wake up the meter to take a measurement periodically, extending battery life. A 300,000-point data logger is built into the unit.
 
Display units can be selected by the user, and the PDFM 5.1 Portable Doppler Flow Meter will display and totalize flow in gallons, liters, cubic feet, or cubic meters. If you change from one measurement system to another, the PDFM 5.1 will automatically and instantly calculate and covert the total flow display and totalizer. Calibrate to the pipe size using the keypad to enter the inside diameter.
 
The 4-20mA output featured on the unit allows you to use the PDFM 5.1 Portable Doppler Flow Meter in critical applications. Ideal applications for this ultrasonic flow meter, with a non-contacting clamp-on ultrasonic sensor include influent and effluent pipe flow, industrial pipe flows, irrigation flows, food and beverage manufacturers, pharmaceutical processes, and many more!

• Clamp-on Ultrasonic Transducer
• Handheld Meter with large backlit LCD Display and Totalizer
• Internal Battery and/or AC Powered
• Built-in 5-Key Calibrator
• 300,000 point Data Logger
• USB Output and Windows software
• 4-20mA Output
• Rugged, watertight Carry Case
 

 

General Specifications
Spec name:Description:
Flow Rate Range± 0.46 m/s to 12.2 m/s (± 0.125 ft/s to 40 ft/s) in most applications
Flow Rate RangeUltrasonic Sensor mounts on any pipe from 12.5 mm to 4.5 m (0.5 in to 180 in) ID
DisplayWhite, backlit matrix - displays flow rate, totalizer, operating mode, and calibration menu
Power InputBuilt-in NiMH battery for up to 18 hours continuous operation External charger with 100-240 V AC 50/60 Hz input
Outputs4-20 mA (500 ohms) when AC powered USB for Data Log transfer by direct PC connection
Data LoggerProgrammable 300,000 data point capacity, time and date stamped or formatted flow reports including total, average, minimum, maximum, and times of occurrence
PC Software'Greyline Logger' for Windows Vista or higher. Retrieves, displays, and saves data log files
Operating Temperature (Electronics)-23 °C to 60 °C (-10 °F to 140 °F)
Electronics EnclosurePortable, ABS enclosure
Carry CaseRated IP67 with protective molded foam insert
Accuracy±2% of reading or 0.03 m/s (0.1 ft/s). Requires solids or bubbles minimum size of 100 microns, minimum concentration 75 ppm. Repeatability: ±0.1%, Linearity ±0.5%
CalibrationBuilt-in 5-key programming with a user-friendly calibration menu. Password protected.
Language SelectionEnglish, French, Spanish
SensitivityAdjustable cut-off, Damping: adjustable
Sensor Specifications
Spec name:Description:
Standard Model PSE4Clamp-on, single-head ultrasonic for pipes from 12.5 mm to 4.5 m (0.5 in to 180 in) ID with 3.4 m (12 ft) shielded dual-coaxial cable
Sensor Mounting KitStainless steel pipe clamp and 150 g (5.3 oz) silicone coupling compound
Operating Temperature-40 °C to 150 °C (-40 °F to 300 °F)

  • Thumbnail of document Pdfm manual 11852
    Download

    Pdfm manual 11852

    Download
  • Thumbnail of document Greyline pdfm 5 1 datasheet 12336
    Download

    Greyline pdfm 5 1 datasheet 12336

    Download

Accessories

Request a Calibration Quote

We’re here to make calibration easy. Request a quote today and let our team give you the care, precision, and service you can trust.
Learn more

Browse By Brands

Uncover the brands that set the standard for quality and dependability in every industry we serve.
Learn more