Skip to main content
Press Enter
Starting at $1,873.00USD
Configure
Precision Digital

PD8-6081 ProtEX-MAX Ex-Proof Ft & Inches Modbus Scanner

Offers all functionality of the PD6081, approved explosion-proof, feet and inches display, dual analog inputs

Starting at
$1,873.00USD
Have questions? We're here to help!
Have questions? We're here to help!
Configure

The ProtEX-MAX™ PD8-6081 feet & inches Modbus® scanner offers all the functionality of the ProVu PD6081 as a fully FM, CSA, ATEX, and IECEx approved explosion-proof product. It displays level information on a specially designed feet & inches display, instead of the usual decimal format. It is the ideal display for hazardous areas with Modbus level or multivariable transmitters and is capable of scanning up to 16 Modbus process variables. Its unique feet & inches upper LED display can indicate up to 99 feet, 11 and 15/16 inches. The 6-digit lower display can indicate units, tags, or other variables such as volume, temperature, or density. The PD8-6081 also has dual analog inputs, for integrating traditional 4-20 mA or voltage inputs in the display scanning. The scanner can be setup as a Modbus master, slave, or snooper. Various math functions may be applied to the analog or Modbus inputs, such as addition, difference, average, and ratio. The PD8-6081 includes a 24 VDC power supply to drive the transmitter and can be equipped with up to four internal relays and two 4-20 mA outputs. It can be programmed and operated without opening the housing by using the built-in SafeTouch® through-glass buttons.

               

Quick Overview

• Input: Modbus with five-wire RS-485 for up to 16 Modbus process variables; two analog inputs, each separately field selectabe; 0-20 mA, 4-20 mA; ±10 VDC (0-5, 1-5, 0-10 V); Modbus PV (slave)
• Display: Dual-line 6-digit, 0.60" (15 mm) & 0.46" (12 mm). Upper feet and inches display: Up to 99 ft, 11 and 15/16 inches.
• Case: Smooth die-cast aluminum explosion-proof
• Power: 85-265 VAC or 12-24 VDC option
• Operating Temperature: -40 to 65°C

• SunBright Display Standard
• Display level in feet and inches
• Modbus RTU master, slave, or snooper mode with RS-485 serial communications
• Master mode to can up to 16 Modbus PVs from Modbus level or multivariable transmitters
• Snooper mode to scan up to 16 Modbus PVs polled by a different Modbus master
• Up to four math channels for addition, difference, average, ratio & more
• SafeTouch® through-glass button programming
• Isolated 24 VDC @ 25 mA transmitter power supply
• 0-20 mA, 4-20 mA, 0-5 V, 1-5 V, and ±10 V inputs
• Onboard USB and ScanView programming software

Under RangeDisplay flashes -99999
Display AssignmentThe top display may be assigned to PV (process values), Ch C (math channel), PV & units, tag & PV, tag-PV-units, C & units, tag-C-unit, Set point 1-8, max/min PV, max/min C. The bottom display may be assigned to all of the above, tag, or off. The tag and units are displayed alternately for 2 sec, when selected. Different tags & PVs may be selected to display on the top and bottom displays at the same time.
Programming MethodsFour through-glass SafeTouch buttons, four mechanical buttons behind glass, digital inputs, PC and ScanView software, or Modbus registers.
F4 Digital Input Contacts3.3 VDC on contact. Connect normally open contacts across F4 to COM.
F4 Digital Input Logic LevelsLogic High: 3 to 5 VDC; Logic Low: 0 to 1.25 VDC
Noise filterProgrammable from 2 to 199 (0 will disable filter)
Filter BypassProgrammable from 0.1 to 99.9% of calibrated span
Input/OutputModbus RTU over RS-485, Two analog inputs (4-20 mA, ±10 V)
DisplayUpper feet & inches display: 0.60" (15 mm) high with feet & inches designations. Lower display: 0.46" (12 mm) high. Both are 6 digits (-99999 to 999999), red LEDs.
Feet & Inches Display Range0" 00" 0/16" to 99" 11" 15/16"
Display IntensityEight user selectable intensity levels
Display Scan RateMaster/Snooper: 1/second to once every 99.9 seconds. Slave: Dependent on master device (e.g. PLC)
Over RangeDisplay flashes 999999
RecalibrationAll ranges are calibrated at the factory. Recalibration is recommended at least every 12 months.
Max/Min DisplayMax (Peak) / min (Valley) readings reached by the process are stored until reset by the user or until power to the meter is cycled.
PasswordThree programmable passwords restrict modification of programmed settings.
Non-Volatile MemoryAll programmed settings are stored in nonvolatile memory for a minimum of ten years if power is lost.
Power Options85-265 VAC 50/60 Hz, 90-265 VDC, 20 W max, or optional model with 12-24 VDC ±10%, 15 W max.
FuseRequired external fuse: UL Recognized, 5 A max, slow blow; up to 6 meters may share one 5 A fuse.
Isolated Transmitter Power SupplyTerminals P+ & P-: 24 VDC ± 10%. Isolated from the input at >500 V. Jumper selectable for 24, 10, or 5 VDC supply (internal jumper J4). All models transmitter supply rated @ 25mA max.
Normal Mode RejectionGreater than 60 dB at 50/60 Hz
Isolation4 kV input/output-to-power line. 500 V input-to-output or output-to-P+ supply.
Overvoltage CategoryInstallation Overvoltage Category II: Local level with smaller transient overvoltages than Installation Overvoltage Category III.
EnvironmentalT6 Class operating temperature range Ta = -40 to 60°C
T5 Class operating temperature range Ta = -40 to 65°C
Max Power DissipationMaximum power dissipation limited to 15.1 W.
ConnectionsRemovable screw terminal blocks accept 12 to 22 AWG wire, RJ45 for external relays, digital I/O, and serial communication adapters.
EnclosureExplosion-proof die cast aluminum with glass window, corrosion resistant epoxy coating, color: blue. NEMA 4X, 7, & 9, IP68. Default conduit connections: Four ¾" NPT threaded conduit openings and two ¾" NPT metal conduit plugs with 12 mm hex key fitting installed. Additional conduit opening configurations may be available; verify quantity and sizes on specific device labeling during installation.
MountingFour slotted flanges for wall mounting or NPS 1½" to 2½" or DN 40 to 65 mm pipe mounting.
Dimensions (W x H x D)6.42" x 7.97" x 8.47" (163 mm x 202 mm x 215 mm)
Weight16.0 lbs (7.26 kg)
USB ConnectionCompatibility: USB 2.0 Standard, Compliant
Connector Type: Micro-B receptacle
Cable: USB A Male to Micro-B Cable
Driver: Windows 98/SE, ME, 2000, Server 2003/2008, XP 32/64-Bit,
Vista 32/64-Bit, Windows 7 32/64-Bit, Windows 10 32/64-Bit
Power: USB Port

Accessories

Request a Calibration Quote

We’re here to make calibration easy. Request a quote today and let our team give you the care, precision, and service you can trust.
Learn more

Browse By Brands

Uncover the brands that set the standard for quality and dependability in every industry we serve.
Learn more