Skip to main content
Press Enter
Buy now! $459.00USD
Precision Digital

PD6300 ProVu Pulse Input Flow Rate/Totalizer

1/8 DIN, displays flow rate and total from a pulse output (NPN, PNP, TTL, switch contact, sine wave, etc.) flowmeter

Buy now!
$459.00USD
Have questions? We're here to help!
Have questions? We're here to help!

The PD6300 is a member of the ProVu series of 1/8 DIN digital panel meters that is specifically designed to display flow rate and total from a pulse output (NPN, PNP, TTL, switch contact, sine wave, etc.) flowmeter. It displays that signal on a dual-line, 6-digit display that is available with optional Sunbright® sunlight readable LEDs. Flow rate is typically displayed on the upper line and the cumulative total is displayed on the lower line. The total overflow feature allows up to a 9-digit total and grand total to be displayed. Like all ProVu meters, the PD6300 includes UL / C-UL listing and CE marking, a NEMA 4X front, and AC or DC power options. ProVu meters can be equipped with up to four internal relays, a 4-20 mA output, and Modbus® RTU serial communications. The PD6300 includes a 24 VDC power supply to drive the flowmeter and can be programmed via the front panel pushbuttons or free MeterView® Pro software.

     

• Gate Function for Rate Display of Slow Pulse Rates
• NEMA 4X, IP65 Front
• Universal 85-265 VAC, or 12/24 VDC Input Power Models
• Isolated 24 VDC Transmitter Power Supply
• Rate Displayed as Units per Second, Minute, Hour, or Day
• Total, Grand Total or Non-Resettable Grand Total
• 9-Digit Totalizer with Total Overflow Feature
• K-Factor Calibration or Scale with up to 32-Point Linearization
• 4-20 mA Output Option Converts the Pulse Input to an Isolated 4-20 mA Output
• Optional SunBright Display Models for Outdoor Applications
• Onboard USB and MeterView® Pro Programming Software

DisplayUpper display: 0.60" (15 mm) high. Lower display: 0.46" (12 mm) high. Both are 6 digits (-99999 to 999999), red LEDs.
Display IntensityEight user selectable intensity levels
Display Update Rate5/second (200 ms)
Over RangeDisplay flashes 999999
Under RangeDisplay flashes -99999
Display AssignmentThe upper and lower displays may be assigned to rate, total, grand total, alternate (rate/total, rate/grand total, rate/units, total/units, and grand total/units), max/min, units (lower display only), set points, or Modbus input. Additional displays are available if parameter total is off, abd parameter d-SCAL is on: gross, alternating gross/net, PV1, PV2, and PCT (refer to PD6000 instruction manual).
Front PanelNEMA 4X, IP65
Programming MethodsFour front panel buttons, digital inputs, PC and MeterView Pro software, Modbus registers
F4 Digital Input Contacts3.3 VDC on contact. Connect normally open contacts across F4 to COM.
F4 Digital Input Logic LevelsLogic High: 3 to 5 VDC
Logic Low: 0 to 1.25 VDC
Noise FilterProgrammable from 2 to 199 (0 will disable filter)
Filter BypassProgrammable from 0.1 to 99.9% of calibrated span
RecalibrationAll ranges are calibrated at the factory. Recalibration is recommended at least every 12 months.
Max/Min DisplayMax (Peak) / min (Valley) readings reached by the process are stored until reset by the user or until power to the meter is cycled.
PasswordThree programmable passwords restrict modification of programmed settings and two prevent resetting the totals.
Non-Volatile MemoryAll programmed settings are stored in non-volatile memory for a minimum of ten years if power is lost.
Power Options85-265 VAC 50/60 Hz, 90-265 VDC, 20 W max or 12-24 VDC ± 10%, 15 W max. Powered over USB for configuration only.
FuseRequired external fuse: UL Recognized, 5 A max, slow blow; up to 6 meters may share one 5 A fuse.
Isolated Transmitter Power SupplyTerminals P+ & P-: 24 VDC ± 10%. 12-24 VDC powered models selectable for 24, 10, or 5 VDC supply (internal P+/P- switch). 85-265 VAC models rated @ 200 mA max, 12-24 VDC powered models rated @ 100 mA max, @ 50 mA max for 5 or 10 VDC supply.
Normal Rejection ModeGreater than 60 dB at 50/60 Hz
Isolation4 kV input/output-to-power line. 500 V input-to-output or output-to-P+ supply.
Overvoltage CategoryInstallation Overvoltage Category II: Local level with smaller transient overvoltages than Installation Overvoltage Category III.
EnvironmentalOperating temperature range: -40 to 65°C
Storage temperature range: -40 to 85°C
Relative humidity: 0 to 90% non-condensing
ConnectionsRemovable screw terminal blocks accept 12 to 22 AWG wire, RJ45 for external relays, digital I/O, and serial communication adapters.
Enclosure1/8 DIN, high impact plastic, UL 94V-0, color: black
Mounting1/8 DIN panel cutout required: 3.622" x 1.772" (92 mm x 45 mm). Two panel mounting bracket assemblies are provided.
Tightening TorqueScrew terminal connectors: 5 lb-in (0.56 Nm)
Dimensions (W x H x D)4.68" x 2.45" x 5.64" (119 mm x 62 mm x 143 mm)
Weight9.5 oz (269 g)
UL File NumberUL & c-UL Listed. E160849; 508 Industrial Control Equipment.
USB ConnectionCompatibility: USB 2.0 Standard, Compliant
Connector Type: Micro-B receptacle
Cable: USB A Male to Micro-B Cable
Driver: Windows 98/SE, ME, 2000, Server 2003/2008, XP 32/64-Bit,
Vista 32/64-Bit, Windows 7 32/64-Bit, Windows 10 32/64-Bit
Power: USB Port
Warranty3 years parts & labor

Accessories

Request a Calibration Quote

We’re here to make calibration easy. Request a quote today and let our team give you the care, precision, and service you can trust.
Learn more

Browse By Brands