Skip to main content
Press Enter
Starting at $1,214.00USD
Configure
Precision Digital

PD2-6100 Helios Strain Gauge, Load Cell & mV Meterv

Ideal for weighing applications or outside in the bright sunlight in temperatures between -40 to 150°F

Starting at
$1,214.00USD
Have questions? We're here to help!
Have questions? We're here to help!
Configure

What sets the Helios apart from other Large Display Meters is its dual line display with super bright LEDs that can be read even in bright sunlight and up to 100 feet away. Based on Precision Digital's popular line of ProVu® digital panel meters, the Helios can satisfy a wide variety of level, flow, temperature, pressure, & weight applications. It is available with models that accept 4-20 mA, thermocouple, RTD, pulse, strain gauge, AC and DC volts and current, and even Modbus®.

Go with the Helios PD2-6100 when you have a weighing application where you need to read the display from a distance, or outside in the bright sunlight in temperatures between -40 to 150°F. The PD2-6100 tare feature can be used to remove the weight of the container from the weight calculation. You can even re-transmit the weight signal with the PD2-6100's optional 4-20 mA output.

Input

15, 30, 150, 300 mV Unipolar Input Ranges;
±15, ±25, ±150, ±250 mV Bipolar Input Ranges


 

Helios Features

• Large 1.80" Digits
• Dual Line Display
• Six Full Digits on Each Line
• Readable From 100 Feet Away
• Superluminous Sunlight Readable Display
• IP65 Rated Field Mountable Enclosure
• Great for Outdoor Use: -40 to 150°F (-40 to 65°C)
• Program the Meter from a PC with Onboard USB and MeterView® Pro

PD2-6100 Features

• Selectable 5 or 10 VDC Sensor Excitation
• Supports up to Twelve (12) 350 Ω Load Cells (Minimum Load Resistance of 28 Ω)
• Capture or Programmable Tare Feature
• Auto-Zero Feature Eliminates Zero Drift
• Ratiometric Operation
• Max/Min or Peak/Valley Hold Feature
• Display One Input in Two Different Scales (e.g. Weight & Volume)
• Rounding Function 1, 2, 5, 10, 20, 50, or 100

DisplayTwo lines with 1.8" (46 mm) high digits, red LEDs; 6 digits per line (-99999 to 999999), with lead zero blanking
Display IntensityEight intensity levels
Display Update Rate5/second (200 ms)
Over RangeDisplay flashes 999999
Under RangeDisplay flashes -99999
Display AssignmentThe upper and lower displays may be assigned to PV1, PV2, PCT (percent), max/min, alternate max & min, set points, units (lower display only), or Modbus input.
Programming MethodsFour SafeTouch through-glass buttons when cover is installed. Four internal pushbuttons when cover is removed.
F4 Digital Input Contacts3.3 VDC on contact. Connect normally open contacts across F4 to COM.
F4 Digital Input Logic LevelsLogic High: 3 to 5 VDC; Logic Low: 0 to 1.25 VDC
Noise filterProgrammable from 2 to 199 (0 will disable filter)
Filter BypassProgrammable from 0.1 to 99.9% of calibrated span
RecalibrationCalibrated at the factory. Recalibration is recommended at least every 12 months.
Max/Min DisplayMax / min readings reached by the process are stored until reset by the user or until power to the meter is turned off.
PasswordThree programmable passwords restrict modification of programmed settings.
Non-Volatile MemoryAll programmed settings are stored in nonvolatile memory for a minimum of ten years if power is lost.
Power Options85-265 VAC 50/60 Hz, 90-265 VDC, 20 W max or 12-24 VDC ± 10%, 15 W max. Powered over USB for configuration only.
FuseRequired external fuse: UL Recognized, 5 A max, slow blow; up to 6 meters may share one 5 A fuse.
Isolated Sensor Power SupplyTerminals Ex+ & Ex-: 10 VDC or 5 VDC ± 10%. Rated @ 350 mA max. Note: Do not use 24 VDC to power strain gauge bridge
Normal Mode RejectionGreater than 60 dB at 50/60 Hz
Isolation4 kV input/output-to-power line. 500 V input-to-output or output-to-P+ supply.
Overvoltage CategoryInstallation Overvoltage Category II: Local level with smaller transient overvoltages than Installation Overvoltage Category III.
EnvironmentalT6 Class operating temperature range Ta = -40 to 60°C
T5 Class operating temperature range Ta = -40 to 65°C
Max Power DissipationPD8 Series: Maximum power dissipation limited to 15.1 W. See PD8 instruction manual for additional details.
Connections Removable screw terminal blocks accept 12 to 22 AWG wire, RJ45 for external relays, digital I/O, and serial communication adapters.
EnclosureUL Type 4X, IP65 rated. Polycarbonate & glass blended plastic case, color: gray. Includes four PG11 through-hole conduit openings, with two factory installed PG11, IP68, black nylon threaded hole plugs with backing nuts.
Wall MountingFour (4) mounting holes provided for screwing the meter into wall.
Pipe MountingOptional pipe mounting kit (PDA6260) allows for pipe mounting. Sold separately.
See PD2-6100 manual for instructions.
Dimensions (H x W x D)10.63" x 12.59" x 4.77" (270 mm x 319.7 mm x 121.2 mm)
Weight6.10 lbs (2.76 kg)
UL File NumberUL & C-UL Listed. E160849; 508 Industrial Control Equipment.
USB ConnectionCompatibility: USB 2.0 Standard, Compliant Connector Type: Micro-B receptacle Cable: USB A Male to Micro-B Cable Driver: Windows 98/SE, ME, 2000, Server 2003/2008, XP 32/64-Bit, Vista 32/64-Bit, Windows 7 32/64-Bit, Windows 10 32/64-Bit Power: USB Port
Warranty3 years parts & labor