Skip to main content
Press Enter
OMEGA

OM-PR150 Submersible Pressure/Temp. Data Loggers

Pressure/Temperature Data Loggers

Normally ships in
2-3 weeks
Have questions? We're here to help!
Have questions? We're here to help!
Configure

Supported Applications

The OM-PR Series is a family of battery-powered, stand-alone, water-tight pressure and temperature data loggers. Each unit is a compact, self-contained recorder that captures up to 64,000 samples of pressure and/or temperature, making it well suited to unattended field studies where a cabled instrument is impractical.

Because the logger is housed in a rugged submersible 316L stainless steel enclosure rated IP67, it can be deployed directly in demanding, wet, and submerged environments. A ¼ NPT male process connection lets it thread into pipes, tanks, and test fittings, and an optional garden hose adaptor supports water-system work. Vacuum-range models extend the same platform to sub-atmospheric measurement.

Each logger can be set to record both pressure and temperature or a single parameter to maximize storage, and is configured with the included Windows software over a direct USB connection. Two independent triggers and multiple trigger modes — instantaneous, button control, on alarm, time and date, and day of week — let the device start and stop logging automatically around an event of interest.

Operating Conditions & Performance

The OM-PR Series measures temperature over -20 to 85°C (-4 to 185°F) with a resolution of 0.1°C (0.1°F). Temperature accuracy is ±1°C, 0 to 50°C (32 to 122°F) and ±2°C, -20 to 85°C (-4 to 185°F).

On the pressure side, accuracy is ±1% with a resolution of 0.01 psia and repeatability of ±0.05%. Each sensor includes 150% Over Range Protection, rated to 1.5 times maximum, to guard against transient overpressure.

Recording behavior is highly configurable:

• Sample rate: user-configured from 1 every 2 seconds to 1 every 24 hours.
• Number of samples: 32,000 or 64,000, depending on setup.
• Record mode: fill to end of memory or cyclic, by number of samples and time duration.
• Alarms: 2 user programmable alarms, high or low.

Power is supplied by an included 1/2AA, 3.6V, 1.2Ah lithium battery, and the replaceable internal battery offers up to a 5-year life, rated up to 5 years at a 1 minute sample rate. Communication is by direct USB connection, and the included software runs on Windows 2000/XP/Vista/7 and 8 (32-bit and 64-bit). The enclosure measures 5.6 H x 5 cm dia (2.19 x 1.95") and weighs 0.9 kg (2.0 lb). The series is CE marked, an optional NIST calibration certificate is available, and OMEGACARE extends the standard 1-year warranty to a total of 2 years.

Configuration Options

All OM-PR loggers share the same submersible 316L stainless steel body, ¼ NPT male port, temperature performance, USB configuration, and recording feature set. The models differ chiefly in their calibrated pressure or vacuum range and in whether they ship with a NIST calibration certificate, following the model number structure OM-PR — Pressure Range — NIST Calibration.

Positive-pressure models are offered across an ascending ladder of full-scale ranges:

• OM-PR35 — 0 to 35 psia.
• OM-PR150 — 0 to 150 psia.
• OM-PR350 — 0 to 350 psia.
• OM-PR550 — 0 to 550 psia.
• OM-PR2000 — 0 to 2000 psia.
• OM-PR5800 — 0 to 5800 psia.

Vacuum-range models cover sub-atmospheric measurement: OM-PR760V for the 760 Torr vacuum range and OM-PR380V for the 380 Torr vacuum range. Every range is available with an optional NIST calibration certificate ordered as the matching -NIST model, which does not change the measurement capability but adds documented, traceable calibration.

Key Product Differences

The ordering lineup pairs each pressure or vacuum range with an optional NIST-certified counterpart:

• OM-PR35 / OM-PR35-NIST — pressure/temperature data logger, 35 psia range.
• OM-PR150 / OM-PR150-NIST — 150 psia range.
• OM-PR350 / OM-PR350-NIST — 350 psia range.
• OM-PR550 / OM-PR550-NIST — 550 psia range.
• OM-PR2000 / OM-PR2000-NIST — 2000 psia range.
• OM-PR5800 / OM-PR5800-NIST — 5800 psia range.
• OM-PR760V — 760 Torr vacuum range.
• OM-PR380V / OM-PR380V-NIST — 380 Torr vacuum range.

Supporting replacement parts and accessories are available for every model:

• OM-PR-BATT — replacement 1/2AA, 3.6V lithium battery.
• OM-PR-ADAPTOR — garden hose adaptor (brass coupling).
• OM-PR-SEAL — replacement O-ring seal (pack of 3).
• OM-PR-COVER — locking anti-theft cover.
• OM-PR-USB-CABLE — replacement 0.9 m (3') USB cable.

• Temperature Range: -20 to 85°C (-4 to 185°F)
• Pressure Ranges: 35, 150, 350, 550, 2000, 5800 psia
• Vacuum Ranges: 760 and 380 Torr
• 150% Over Range Protection
ApprovalsCE
Battery lifeup to 5 yr
Battery Size and Type3.6V Li-ion
Calibration AccuracyTemperature : ±2 °C, Pressure : ±1%
Control Output2 Programmable Alarms
Data InterfaceUSB
Diameter50 mm
Height56 mm
Materials316L Stainless Steel
Measurement TypePressure, Temperature
Measuring Temperature Range, Max85 °C
Measuring Temperature Range, Min-20 °C
Memory32,000 or 64,000 (depends on setup)
Millivolt RangeN/A
Number of Measurements2
Operating Temperature, Max85 °C
Operating Temperature, Min-20 °C
Measurement Pressure, Min0 psi
Pressure Repeatability±0.05%
Process Connection Size1/4 in
Process Connection TypeNPT Male
Proof Pressure150% Full Scale
Record Trigger NoteRecord Trigger: Two independent triggers Multiple Trigger Modes: Instantaneous, button control, on alarm, time and date (Start and Stop), day of week Record Mode: Fill to end of memory or cyclic, number of samples and time duration
Sampling Rate0.5 Hz (2 seconds between updates)
Sampling Rate NoteUser configured 1 every 2 seconds to 1 every 24 hours
Series IDOM-PR-Series
SoftwareWindows 2000/XP/Vista/7 and 8 (32-bit and 64-bit)
Supply Power TypeBattery
Weight900 g

Request a Calibration Quote

We’re here to make calibration easy. Request a quote today and let our team give you the care, precision, and service you can trust.
Learn more

Browse By Brands

Uncover the brands that set the standard for quality and dependability in every industry we serve.
Learn more