Supported Applications
The OM-PR Series is a family of battery-powered, stand-alone, water-tight pressure and temperature data loggers. Each unit is a compact, self-contained recorder that captures up to 64,000 samples of pressure and/or temperature, making it well suited to unattended field studies where a cabled instrument is impractical.
Because the logger is housed in a rugged submersible 316L stainless steel enclosure rated IP67, it can be deployed directly in demanding, wet, and submerged environments. A ¼ NPT male process connection lets it thread into pipes, tanks, and test fittings, and an optional garden hose adaptor supports water-system work. Vacuum-range models extend the same platform to sub-atmospheric measurement.
Each logger can be set to record both pressure and temperature or a single parameter to maximize storage, and is configured with the included Windows software over a direct USB connection. Two independent triggers and multiple trigger modes — instantaneous, button control, on alarm, time and date, and day of week — let the device start and stop logging automatically around an event of interest.
Operating Conditions & Performance
The OM-PR Series measures temperature over -20 to 85°C (-4 to 185°F) with a resolution of 0.1°C (0.1°F). Temperature accuracy is ±1°C, 0 to 50°C (32 to 122°F) and ±2°C, -20 to 85°C (-4 to 185°F).
On the pressure side, accuracy is ±1% with a resolution of 0.01 psia and repeatability of ±0.05%. Each sensor includes 150% Over Range Protection, rated to 1.5 times maximum, to guard against transient overpressure.
Recording behavior is highly configurable:
• Sample rate: user-configured from 1 every 2 seconds to 1 every 24 hours.
• Number of samples: 32,000 or 64,000, depending on setup.
• Record mode: fill to end of memory or cyclic, by number of samples and time duration.
• Alarms: 2 user programmable alarms, high or low.
Power is supplied by an included 1/2AA, 3.6V, 1.2Ah lithium battery, and the replaceable internal battery offers up to a 5-year life, rated up to 5 years at a 1 minute sample rate. Communication is by direct USB connection, and the included software runs on Windows 2000/XP/Vista/7 and 8 (32-bit and 64-bit). The enclosure measures 5.6 H x 5 cm dia (2.19 x 1.95") and weighs 0.9 kg (2.0 lb). The series is CE marked, an optional NIST calibration certificate is available, and OMEGACARE extends the standard 1-year warranty to a total of 2 years.
Configuration Options
All OM-PR loggers share the same submersible 316L stainless steel body, ¼ NPT male port, temperature performance, USB configuration, and recording feature set. The models differ chiefly in their calibrated pressure or vacuum range and in whether they ship with a NIST calibration certificate, following the model number structure OM-PR — Pressure Range — NIST Calibration.
Positive-pressure models are offered across an ascending ladder of full-scale ranges:
• OM-PR35 — 0 to 35 psia.
• OM-PR150 — 0 to 150 psia.
• OM-PR350 — 0 to 350 psia.
• OM-PR550 — 0 to 550 psia.
• OM-PR2000 — 0 to 2000 psia.
• OM-PR5800 — 0 to 5800 psia.
Vacuum-range models cover sub-atmospheric measurement: OM-PR760V for the 760 Torr vacuum range and OM-PR380V for the 380 Torr vacuum range. Every range is available with an optional NIST calibration certificate ordered as the matching -NIST model, which does not change the measurement capability but adds documented, traceable calibration.
Key Product Differences
The ordering lineup pairs each pressure or vacuum range with an optional NIST-certified counterpart:
• OM-PR35 / OM-PR35-NIST — pressure/temperature data logger, 35 psia range.
• OM-PR150 / OM-PR150-NIST — 150 psia range.
• OM-PR350 / OM-PR350-NIST — 350 psia range.
• OM-PR550 / OM-PR550-NIST — 550 psia range.
• OM-PR2000 / OM-PR2000-NIST — 2000 psia range.
• OM-PR5800 / OM-PR5800-NIST — 5800 psia range.
• OM-PR760V — 760 Torr vacuum range.
• OM-PR380V / OM-PR380V-NIST — 380 Torr vacuum range.
Supporting replacement parts and accessories are available for every model:
• OM-PR-BATT — replacement 1/2AA, 3.6V lithium battery.
• OM-PR-ADAPTOR — garden hose adaptor (brass coupling).
• OM-PR-SEAL — replacement O-ring seal (pack of 3).
• OM-PR-COVER — locking anti-theft cover.
• OM-PR-USB-CABLE — replacement 0.9 m (3') USB cable.
| Approvals | CE |
| Battery life | up to 5 yr |
| Battery Size and Type | 3.6V Li-ion |
| Calibration Accuracy | Temperature : ±2 °C, Pressure : ±1% |
| Control Output | 2 Programmable Alarms |
| Data Interface | USB |
| Diameter | 50 mm |
| Height | 56 mm |
| Materials | 316L Stainless Steel |
| Measurement Type | Pressure, Temperature |
| Measuring Temperature Range, Max | 85 °C |
| Measuring Temperature Range, Min | -20 °C |
| Memory | 32,000 or 64,000 (depends on setup) |
| Millivolt Range | N/A |
| Number of Measurements | 2 |
| Operating Temperature, Max | 85 °C |
| Operating Temperature, Min | -20 °C |
| Measurement Pressure, Min | 0 psi |
| Pressure Repeatability | ±0.05% |
| Process Connection Size | 1/4 in |
| Process Connection Type | NPT Male |
| Proof Pressure | 150% Full Scale |
| Record Trigger Note | Record Trigger: Two independent triggers Multiple Trigger Modes: Instantaneous, button control, on alarm, time and date (Start and Stop), day of week Record Mode: Fill to end of memory or cyclic, number of samples and time duration |
| Sampling Rate | 0.5 Hz (2 seconds between updates) |
| Sampling Rate Note | User configured 1 every 2 seconds to 1 every 24 hours |
| Series ID | OM-PR-Series |
| Software | Windows 2000/XP/Vista/7 and 8 (32-bit and 64-bit) |
| Supply Power Type | Battery |
| Weight | 900 g |