Supported Applications

The OM-CP-TCTEMPX Series is a family of multi-channel thermocouple temperature data loggers available in 4, 8, 12, and 16-channel configurations. Because each unit can monitor and record many thermocouple inputs at once, it is suited to multi-point temperature monitoring and thermal profiling where several locations must be tracked simultaneously.

Support for J, K, T, E, R, S, B, and N type thermocouples lets the loggers cover applications ranging from low-temperature environments to high-temperature process measurement. Individual cold junction compensation per channel and open channel detection make the series appropriate for demanding industrial and laboratory temperature recording, and each unit ships with a NIST traceable calibration certificate for quality and compliance documentation.

• Multi-point industrial temperature monitoring
• Thermal profiling across multiple locations
• Laboratory and process temperature recording
• Applications requiring NIST traceable calibration

Operating Conditions & Performance

The internal channels measure over a temperature range of -20 °C to +60 °C (-4 °F to +140 °F) with a resolution of 0.01 °C (0.018 °F) and a calibrated accuracy of ±0.5 °C (0 °C to 50 °C). The loggers operate in an environment of -20 °C to +60 °C (-4 °F to +140 °F) and 0 %RH to 95 %RH non-condensing.

Remote thermocouple channels connect through a female subminiature (SMP) connection and accept a maximum thermocouple resistance of 1000 Ω, <100 Ω recommended, with automatic cold junction compensation based on the internal channel. Accuracy is ±0.5 °C for J, K, T, E, N thermocouples and ±2.0 °C for R, S, B thermocouples.

The reading rate ranges from 4 Hz up to 1 reading every 24 hours. Memory capacity with all channels enabled is 524,032 readings per channel on the 4-channel model, 262,016 readings per channel on the 8-channel model, 174,677 readings per channel on the 12-channel model, and 131,008 readings per channel on the 16-channel model. Data is date and time stamped in °C, °F, K, °R, mV, V, and time accuracy is ±1 minute/month.

Each unit uses a 9 V lithium battery (included and user replaceable) with an 18 months typical battery life, and connects through a USB-A to micro USB cable (included) at 460,800 baud. Start modes include software programmable immediate start or delay start, up to 6 months in advance, with digital calibration through software. The series carries CE and ROHS approvals.

Configuration Options

The four members of the series differ primarily in channel count, physical size, weight, and memory depth. The 4-channel and 8-channel models share dimensions of 2.70 in x 7.25 in x 1.22 in (65.6 mm x 184.2 mm x 31.0 mm) and weigh 13 oz (368 g). The 12-channel model measures 2.70 in x 7.25 in x 1.68 in (65.6 mm x 184.2 mm x 42.7 mm) and weighs 20 oz (580 g), while the 16-channel model measures 2.70 in x 7.25 in x 2.14 in (65.6 mm x 184.2 mm x 54.4 mm) and weighs 28 oz (800 g).

All variants accept the same thermocouple types and share the same accuracy and resolution behavior. Type J covers -210 °C to +760 °C, type K covers -270 °C to +1370 °C, type T covers -270 °C to +400 °C, type E covers -270 °C to +980 °C, type N covers -270 °C to +1300 °C, type R covers -50 °C to +1760 °C, type S covers -50 °C to +1760 °C, and type B covers +50 °C to +1820 °C.

Every variant provides individual cold junction compensation per channel, open channel detection, configurable channel names, and real time recording with a PC. The OM-CP-BAT103 replacement battery allows user servicing across all models.

Key Product Differences

• OM-CP-QUADTCTEMP-A2 - 4-Channel Thermocouple Data Logger
• OM-CP-OCTTCTEMP-A2 - 8-Channel Thermocouple Data Logger
• OM-CP-X12TCTEMP-A2 - 12-Channel Thermocouple Data Logger
• OM-CP-X16TCTEMP-A2 - 16-Channel Thermocouple Data Logger
• OM-CP-BAT103 - Replacement 9V lithium battery

  • Multi-channel thermocouple logger (4–16 channels) with fast 4 Hz sampling for precision temperature tracking
  • Supports J, K, T, E, R, S, B, and N thermocouples with cold junction compensation for superior accuracy
  • Configurable channel names and logging intervals simplify setup and streamline data organization
  • Battery or external power options, USB download, and NIST-traceable accuracy for industrial reliability

 

CalibrationDigital calibration through software
Data InterfaceWiFi
Data Interface NoteUSB-A to micro USB cable (included); 460,800 baud
Electrical ConnectionScrew Terminal
EnclosureAluminium
Form factorBenchtop
LED Indicators1 per channel and 2 status LEDs
Length65.6 mm
Operating Humidity0 to 95% RH
Operating Temperature, Max60 °C
Operating Temperature, Min-20 °C
Process Temperature, Max60 °C
Process Temperature, Min-20 °C
Real Time RecordingMay be used with PC to monitor and record data in real time
Samples,Max2000000
Sampling Rate1 day
Sampling Rate Note4 Hz up to 1 reading every 24 hours
Series IDOM-CP-XTCTemp-Series
Software CompatibilityWindows® XP/VISTA/7 and 8 (32- and 64-bit)
Supply Power TypeBattery
Temperature Accuracy± 0.5 °C
Temperature Resolution0.01 °C
Temperature Sensor TypeThermocouple
Thermocouple Resistance, Max1000 Ω
1000 Ω± 1 minute/month
Width184.2 mm
Wire Gauge24 AWG

  • Download

    OM CP TCTEMPX Series User Guide 16496

    Download
  • Download

    OM CP TCTEMPX Series Spec Sheet 16495

    Download

Request a Calibration Quote

We’re here to make calibration easy. Request a quote today and let our team give you the care, precision, and service you can trust.
Learn more

Browse By Brands

Uncover the brands that set the standard for quality and dependability in every industry we serve.
Learn more