Supported Applications
The Omega OM-CP-RFRTDTEMP2000A is an RTD-based, wireless temperature data logger with display. The series identity centers on high accuracy temperature monitoring within laboratories and the pharmaceutical and biotech industries.
Operating Conditions & Performance
This device accepts 2, 3 or 4 wire 100Ω platinum RTD sensors. It features a documented device accuracy of ±0.05°C. Recalibration is recommended annually at 25°C and 60°C.
Configuration Options
The series supports wireless communication via the OM-CP-RFC1000-EXT interface device or plugged-in operation using a USB cable. Power options include battery replacement with the OM-CP-BAT103 battery.
• Interface: Wireless (via OM-CP-RFC1000-EXT) or USB cable
• Sensor Input: 2, 3, or 4 wire 100Ω platinum RTD
• Battery Option: OM-CP-BAT103 battery for replacement
Key Product Differences
The series is identified by the model number guide OM-CP-RFRTDTEMP2000A. The device carries a 5-year warranty and is made in the USA. Corporate quality certifications include CE, ISO 9001 Certified (Stamford, CT), and ISO 9001 Certified (Manchester, UK).
| Alarm Note | Programmable high and low limits; alarm is activated when temperature reaches or exceeds set limits, Alarm Delay: A cumulative alarm delay may be set in which the device will activate the alarm (via LED) only when the device has recorded a user specified time duration of dataAudible Alarm Functionality: 1 beep per second for reading alarm above/below threshold |
| Band Frequency | 2.405 to 2.475 GHz |
| Band Frequency Note | ISM band 2.405 to 2.475 GHz operation (channels 11 through 25) @ 250 kbps data rate |
| Battery life | 4 yr, typical with reading interval of 1 min |
| Battery Size and Type | Li-ion, 9V |
| Baud Rate | 250000 |
| Calibration | Digital Calibration through Software |
| Calibration Accuracy | Temperature: ± 0.05 °C |
| Calibration Date | Automated |
| Configuration | Omega Data Logging Software, Windows PC |
| Data Interface | Wireless, USB |
| Data Interface Note | USB to mini USB, 250,000 baud for standalone operation or OM-CP-RFC1000-EXT/ OM-CP-RFC1000-EXT-EUR/OM-CP-RFC1000-IP69K required for wireless operation |
| Display | LCD |
| Form factor | Wall Mount |
| Height | 0.95 in |
| Input Type | Internal |
| LED Functionality | Green LED blinks every 5 seconds to indicate unit is logging, Blue LED blinks every 15 seconds to indicate unit is in wireless mode, Red LED blinks every 1 second to indicate alarm condition |
| Length | 3.25 in |
| Materials | Plastic |
| Measurement Type | Temperature |
| Number of Measurements | 1 |
| Operating Temperature, Max | 60 °C |
| Operating Temperature, Min | -20 °C |
| Output Power, Max | +0dBm |
| Pressure Resolution | 0.02 mbar |
| Pulse Resolution | ≤10 µS |
| Relative Humidity | 0 to 95% RH non-condensing |
| Response Time | Temperature: 10 min |
| Response Time Note | Temperature: 10 min free air |
| RF Frequency | 2.45 GHz |
| RF Frequency Note | 2.45GHz IEEE 802.15.4 ultra-low power wireless transceiver with fully bi-directional communication |
| RH Resolution | 0.001 |
| RTD Type | 2, 3 or 4-wire 100Ω Pt RTD, α= 0.00385 |
| Samples,Max | 21504 Samples, Interval Selectable 1 Sec to 24 hrs |
| Series ID | OM-CP-RFRTDTEMP2000A-Series |
| Software | XP SP3/Vista/7 and 8 (32 and 64-bit) |
| Supply Power Note | Ultralife 9V lithium battery included; user replaceable |
| Supply Power Type | Battery |
| Temperature Measurement, Max | 850 °C |
| Temperature Measurement, Min | -200 °C |
| Time Accuracy | ± 1 minute/month |
| Weight | 4.1 oz |
| Width | 3.5 in |