OM-CP-OCTPRO 8 Channel Programmable Portable Data Logger

Eight Channels Programmable Portable Data Logger-Touch Screen

Normally ships in
2-3 weeks
Have questions? We're here to help!
Have questions? We're here to help!

Supported Applications

The Omega OM-CP-OCTPRO is an 8-channel programmable portable data logger featuring a capacitive touchscreen interface. It measures and records temperature, current, voltage, frequency, and pulse inputs simultaneously while displaying data in real time without requiring a PC or downloaded software for operation.

• Industrial engineering
• Quality assurance
• Compliance monitoring
• Automotive technician applications

Operating Conditions & Performance

The series supports simultaneous measurement across eight channels with the following documented input ranges:

• Current: -5 mA to 50 mA
• Voltage (Volt): -0.5 V to 12.0 V
• Voltage (Millivolt): -100 mV to 2450 mV
• Frequency: 0 to 25,000 Hz (port 1 only)
• Pulse / Counter: 0 to 4,000,000,000 Pulses (port 1 only)

Temperature measurement capabilities include support for thermistors, RTDs, and multiple thermocouple types with the following ranges: - Thermistor NTC-1 (2252): -25 °C to +150 °C - Thermistor NTC-2 (10K): -25 °C to +150 °C - PT100 RTD 2-Wire, 3-Wire, and 4-Wire: -200 °C to +850 °C - Thermocouple J: -210 °C to +760 °C - Thermocouple K: -270 °C to +1370 °C - Thermocouple T: -270 °C to +400 °C - Thermocouple E: -270 °C to +980 °C - Thermocouple R and S: -50 °C to +1760 °C - Thermocouple N: -270 °C to +1300 °C - Thermocouple B: +50 °C to +1820 °C

Configuration Options

The OM-CP-OCTPRO is configured as an all-in-one data collection and monitoring solution. Key configurable or supported features include:

• Sensor Compatibility: Compatible with thermocouple, RTD, or thermistor probes; voltage output sensors; current switches; transmitters; and transducers.
• User Interface: Built-in capacitive touchscreen graphic display for easy configuration and operation.
• Data Management: USB Port provided for offloading data files and updating device software.

Key Product Differences

The series is represented by the single model OM-CP-OCTPRO. The documentation does not list alternative housing styles, enclosure ratings, or distinct sub-models within this specific product family snapshot.

  • Touchscreen interface allows easy configuration without a PC or software
  • Measures temperature, current, voltage, and pulse across 8 channels simultaneously
  • Compatible with thermocouples, RTDs, thermistors, and voltage-output sensors
  • Built-in memory stores data with real-time display and downloadable USB output
AC Power Plug TypeN/A
Accuracy± 0.1 %
Accuracy DetailCurrent Accuracy: ±0.024 mA Voltage Accuracy: ±0.1 mV, ±0.01 V Thermistor Accuracy: ±0.50% RTD Accuracy: ±0.1 °C Thermocouple Accuracy: J, K, T, E, N: ±0.5 °C R, S, B: ±2.0 °C
Battery Size and Type3.7V Li-ion
CalibrationFactory calibration is recommended annually
Data InterfaceUSB
Dimensions Note6.65 in x 4.40 in x 1.41 in (168.9 mm x 111.8 mm x 35.8 mm) Data logger only
Display NoteLCD Touchscreen: 5 inch LCD capacitive touchscreen.
Display TypeLCD
Enclosure RatingsIP20
Frequency Input Range0 to 25 kHz
Height6.65 in
Impedance InputCurrent Input Impedance: 30Ω,Voltage Input Impedance: 1 GΩ,Frequency Input Impedance: 58 kΩ
Input Control SignalMillivolt input: -100 to 2450 mV Volt input: -0.5 V to 12.0 V
Input Current-5 to 50 mA
Input TypeThermocouple, RTD, Thermistor, Current,Voltage, Digital
Length1.41 in
MaterialsPolycarbonate
Memory1,000,000 or 5,000,000 Readings
Memory Note1,000,000 or 5,000,000 Readings
MountingHandheld, Tabletop or Wall Mounting
Pulse Input Note0 to 4,000,000,000 Pulses
Relative Humidity0 to 95% RH non-condensing
Resolution0.1 °C
Resolution NoteCurrent Resolution: 0.0001 mA Voltage Resolution: 0.0001 mV, 0.0001 V RTD Resolution: 0.01 °C Thermisor Resolution: 0.01 °C Thermocouple Resolution: J, K, T, E, N: 0.1 °C R, S, B: 0.5 °C
Sampling Rate4 kHz
Series IDOM-CP-OCTPRO-Logger
Supply Power Note• Rechargeable 3.7 V Lithium Ion Battery, • Continuous on-screen sampling: 9 hours; Stand-by mode: 100 hours
Supply Power TypeUSB
Temperature Measurement RangeJ: -200 to 760 °C,K: -270 to 1370 °C,T: -270 to 400 °C,E: -270 to 980 °C,R: -50 to 1760 °C,S: -50 to 1760 °C,N: -270 to 1300 °C,B: 50 to 1820 °C,RTD: -200 to 850 °C,TH 2252Ω, 10KΩ: -25 to 150°C
Thermocouple TypeJ, K, T, E, N, R, B, S
Weight1.3 lb
Width4.4 in
Wiring/Connector Table2-, 4-Wire RTD
• Process Monitoring
• Machine efficiency studies
• Multi-use Laboratory and R&D applications
 

Request a Calibration Quote

We’re here to make calibration easy. Request a quote today and let our team give you the care, precision, and service you can trust.
Learn more

Browse By Brands

Uncover the brands that set the standard for quality and dependability in every industry we serve.
Learn more