Skip to main content
Press Enter
OMEGA

OM-CP Intrinsically Safe Temperature & Humidity Data Logger

Intrinsically Safe Temperature and Humidity Data Logger

Normally ships in
3-4 weeks
Have questions? We're here to help!
Have questions? We're here to help!

Supported Applications

The OM-CP-RHTEMP1000IS-A2 is an intrinsically safe temperature and humidity data logger designed for hazardous locations. Its 316 stainless steel enclosure, fast response and intrinsically safe certification make it suited to demanding, potentially explosive environments where both temperature and humidity must be documented.

• EtO sterilization processes.
• Environmental studies.
• Hazardous locations certified as Class 1 Division 1 Group ABCD and Class 1 Division 2 Group ABCD, Temperature Class: T4A.

Operating Conditions & Performance

Temperature is measured by a Resistance Temperature Detector (RTD) and humidity by a Capacitive Polymer sensor over the following ranges:

• Temperature: -40 °C to +80 °C (-40 °F to +176 °F)
• Humidity: 0 %RH to 100 %RH (non-condensing)

Temperature resolution is 0.01 °C (0.018 °F) with a calibrated accuracy of ±0.5 °C (0 °C to ±50 °C), ±0.9 °F (32 °F to 122 °F). Humidity resolution is 0.1 %RH with a calibrated accuracy of ±3.0 %RH maximum. The specified accuracy range is 25 %RH to 75 %RH, +20 °C to +40 °C (68 °F to 104 °F) with a Hysteresis Error of 1 % Typical, 3 % Maximum.

The logger holds 32,768 Readings and records at a reading rate of 1 reading every second up to 1 reading every 24 hours, and may be used with a PC to monitor and record data in real time. It is powered by a Tadiran TL-2150 3.6V lithium battery, included and user replaceable in a non-hazardous location, with a battery life of 2 years typical at 15 minute reading rate. Data is date and time stamped in °C, °F, K, °R; %RH, mg/mL, Dew Point, and time accuracy is 16 seconds / month across -40 °C to 80 °C.

The enclosure is 316 Stainless Steel/Radel, measuring 1.67 in x 0.97 in dia. (42.3 mm x 24.6 mm dia.) and weighing 2.4 oz (68 g). The device is not rated for submersion; do not submerge this product to retain the IS rating. Approvals include CE, FM Class 3600, Rev. Jan 2018, FM Class 3610, Rev. Jan 2018, CAN/CSA-C22.2 No. 60079-0:15 and CAN/CSA-C22.2 No. 60079-11:14.

Configuration Options

This series is a single logger configuration, the OM-CP-RHTEMP1000IS-A2, combining an RTD temperature channel and a Capacitive Polymer humidity channel in one intrinsically safe stainless steel housing. Its capabilities and workflow options include:

• Programmable recording: software programmable immediate or delay start, up to 24 months in advance, with digital calibration through software and calibration date automatically recorded within the device.
• Process analysis: Sterilization Units and Pasteurization Units lethality equations are available within the software.
• Data retrieval: the OM-CP-IFC400 docking station connects a single logger by USB cable, while the OM-CP-IFC406 is a 6 Port, Multiplexer docking station for reading multiple loggers.
• Battery: the OM-CP-BAT113 is the replacement 3.6 V lithium battery, user replaceable in a non-hazardous location.

Key Product Differences

The series is ordered from the following model and accessories:

• OM-CP-RHTEMP1000IS-A2 - Intrinsically Safe Temperature and Humidity Data Logger.
• OM-CP-IFC400 - Docking station with USB cable.
• OM-CP-IFC406 - 6 Port, Multiplexer docking station with USB cable.
• OM-CP-BAT113 - Replacement 3.6 V lithium battery.

  • Certified Intrinsically Safe
  • SGS Certified to meet FM3600 and FM3610 standards
  • Software Battery Life Indicator
  • NIST Certified

 

Additional Features 1SGS, FM, Intrinsically Safe
Battery lifeup to 2 yr
Battery Size and TypeAlkaline
CalibrationDigital calibration through software
Data InterfaceUSB
Data Interface NoteOM-CP-IFC400 or OM-CP-IFC406
Materials316 Stainless Steel/Radel
Measurement TypeHumidity, Temperature
Memory32767
Number of Measurements2
Operating Temperature, Max80 °C
Operating Temperature, Min-40 °C
Real Time RecordingMay be used with PC to monitor and record data in real time
Relative Humidity Accuracy± 3% RH
Relative Humidity Accuracy Note25 %RH to 75 %RH +20 °C to +40 °C (68 °F to 104 °F) Hysteresis Error 1 % typical, 3 % Maximum
Relative Humidity, Max1
Relative Humidity, Min0%
Relative Humidity Resolution0.001
Relative Humidity Sensor TypeCapacitive Polymer
Samples,Max32768
Sampling Rate1 Hz (1 update/second)
Sampling Rate Note1 reading every second to 1 every 24 hours.
Series IDOM-CP-RHTEMP1000IS-Lgr
Software CompatibilityWindows XP SP3/7/8/10
Supply Power TypeBattery
Temperature Measurement, Max80 °C
Temperature Measurement, Min-40 °C
Temperature Measurement Note-40°C to +80°C(-40 °F to +176°F)
Temperature Resolution0.01 °C
Temperature Sensor TypeRTD
Temperature Sensor Type NoteResistance Temperature Detector(RTD)
Time Accuracy16 sec/month
Weight68 g
  • Download

    OM CP RHTEMP1000 IS Lgr spec 16521

    Download
  • Download

    OM CP RHTEMP1000 IS Lgr manual 16522

    Download

Request a Calibration Quote

We’re here to make calibration easy. Request a quote today and let our team give you the care, precision, and service you can trust.
Learn more

Browse By Brands

Uncover the brands that set the standard for quality and dependability in every industry we serve.
Learn more