OM-240 is a versatile, high accuracy “smart” data acquisition system. It provides 24 differential analog inputs, individually configured.

 
The Data Logger can be used in a wide range of applications, including HVAC, oil and gas, water quality, energy and building monitoring. Using OM-240 requires no additional configuration/analysis software package, as it is provided by an Embedded Web Server. Only a standard Web Browser (Firefox recommended) for configurations and data view. Logged Data is ready to be shown in a graphic “real time” mode (License required) or exported in a CSV file. Channel expansion provided by multiplexers. There are 8 terminal blocks (each terminal block can handle up to 3 sensors). The OM-240 is designed to work with 2 to 6-wire sensors. You can connect 2-wire sensors on each channel and read 24 sensors, or 4-wire sensor and read 12 channels. The system will order sensors depending on how many wires they use, placing 6 wires sensors first, 4 wires in the middle, and 2 wires last.
 
Once software configuration is done, clicking on “Wiring scheme” button on the web interface near the sensors will show how to connect the chosen sensor to the block physically. It shows “relative” position, so if you start connecting sensors from the first, you will not have to leave “unused” positions (except for the ground connection of every block, if not used). Multiplexers are needed if the total “wires” from sensors exceeds the 48 provided by the OM-240.
Applications including Oil/Gas Pipeline Monitoring, Building/Bridge Structure Health Monitoring, Engine Thermal Mapping Testing, Data Center Environmental Monitoring, and Energy Farm Monitoring, and etc.
 
• Omega Enterprise Gateway Compatible
• 24 Differential, Independent Analog Input Channels, 2 Digital Inputs and 1 Digital Output
• On-Board Web Server for Setup, Data View, and Diagnostic
• Independent Thermocouples, PT100/200/500/1000, NTC, mV, mA, mV/V, Vibrating Wire
Weight980 g (2.16 lb)
Dimensions231 L x 138 W x 117 mm H (9.09 x 5.43 x 4.61”)
MaterialPlastic and metal
WiringRemovable screw terminal connectors
Measurement Rate
Analog Initialization (±10V range)
Maximum Speed1.70 sec
Standard Speed7.10 sec
Instrument Warm-UpDepends on sensor configuration
Measurement (±10V range:
Maximum Speed80 ms
Standard Speed1.57 sec
NotesTimes indicated are not valid for vibrating wire measures Init analog phase is made only once before measurement cycle
Measure Frequency Selectable (Global or for Each Channel)1 second up to 1 week
ADC24-bit (22 true bit) differential analog-to-digital converters, 5SPS to 1000SPS, 0-24 average function, auto-calibration and auto-range
CPU and MEMORY
ProcessorARM Cortex-M3 MCU with 1 MB Flash, 120 MHz CPU, ART Accelerator, Ethernet
RAM Memor1 Mbyte RAM
Mass Storage2 GB SD card for data (about 5 Mega data points) and Web pages
Clock AccuracyRTC (real time clock with battery back-up) temperature compensated
On-Board SensorsTemperature (accuracy ±1%), measured inside the datalogger
Switched Output Power SupplyThe voltage ‘V OUT' is switched on and off under program control. V OUT is the unregulated input power supply ‘V IN' (2 A Max)
SOFTWARE and FIRMWARE
Web Server on Board(independent OS platform)
Acquisition Time IntervaSelectable from 1 second up to 1 week (depends on the number of channels acquired)
FTP clientTo send data/alarms on an FTP server (SFTP not supported)
MAIL to send data/alarmTo max 5 email address (SMTPS / SSL not supported)
SMS to Send AlarmsTo max 5 telephone numbers
Data Download(measure, logs) in .csv file (compatible with Microsoft Excel)
Virtual Channels ManagementFor Math operations between channels
ANALOG INPUTSThermocouple, RTD (Pt100, Pt200, Pt500, Pt1000), Thermistor, Current Loop, Current Transmitter, Voltage, Servo Inclinometer, Wheatsonte Bridge, Potentiometer, Vibrating Wire
Temperature Drift< 10 ppm/°C, range -30 to 70°C (-22 to 158ºF)
Input Noise Voltage5.42 µV pp
Input Limits±12V
DC Common Mode Rejection>105 dB
Normal Mode Rejection>90 dB
Input Impedance20 MΩ typical
THERMOCOUPLES
Thermocouple TypesK, B, J, T, E, R, N, S
Resolution1 µV at FS for ±10 mV range;
10 µV at FS for ±100 mV range;
100 µV at FS for ±1 V range;

 

 

Request a Service Quote