Skip to main content
Press Enter
Rice Lake Weighing Systems

Minebea Intec PR5220 TCP/IP Ethernet Transmitter

Minebea Intec PR5220 TCP/IP Ethernet Transmitter

Have questions? We're here to help!
Have questions? We're here to help!

 The PR5220 Ethernet transmitter sets new standards in process instrumentation. The standard Ethernet TCP/IP interface enables easy transmission of information to superordinate systems.

• Configuring via VNC
• OPC server
• Full digital signal processing with up to 4.8 Mio divisions internal resolution
• SmartCalibration feature for fast calibration even without weights
• Requires supply voltage of 24 VDC
• IP20 housing, DIN Rail Mount
• Verifiable with remote display up to 10,000 e, CL III (EN 45501, OIML R76)
• Precision analog output
• Serial RS-485/422 interface
• CD supplied with software suite
• 10,000 divisions at six samples per second
Approvals10,000 e class III acc. to EN 45501; according to. OIML R76, min. verification interval: 0.5 μV/e
WeightVersion 00:
Net: 0.29 kg
Versions 01, 04, 06, 07
Net: 0.35 kg
TemperatureWandM: 14 °F to 104 °F (–10 °C to 40 °C)
Operation: 14 °F to 122 °F (–10 °C to 50 °C)
Storage: -40 °F to 158 °F (–40 °C to 70 °C)
Electrical ConnectionsAll electrical connections via modular screw terminals for 2.5 mm 2 max. System Phoenix/COMBICO
Serial InterfacesRS422/485 via screw terminals
Protocol: Remote display, SMA and Minebea digital scales (XBPI–protocol)
Analogue Output0 to 10 or 4-20 mA, internal resolution 16-bit, usable step-width: 0.5 μA max. load 500 O; user configurable
Status IndicatorStatus LEDs to signal operation and error conditions.
Ethernet Interface (Functions)Ethernet IP and Modbus/TCP
Definition of an IP address: – AutoIP; – DHCP Server classification; – manual entering of an IP address
Automatic detection of signal transmission and corresponding change over (cross-over or patch cable) Webservice via SOAP|UPnP (Simple Object Access Protocol) Synchronal Modbus UDP
Digital Filter for Load Cell4th order (low pass), Bessel, aperiodic or Butterworth
Temperature EffectsZero: TK0 m < 0.02 μV/K RTI
Span: TKspan < +/- 2 ppm/K
Linearity< 0.002 %
Input SignalMeasuring signal: 0 to 36 mV (for 100 % nominal load)
Input Range7.5 mV (appr. 4.8 Mio. div.)
Usable resolution: 0.2 μV/d
Measuring PrincipleMeasuring amplifier: Delta-Sigma converter
Measuring time: min 5 ms - max. 1600 ms
Minimum Load ImpedanceMin. 75 ohm e.g. 6 load cells with 600 ohm or 4 load cells with 350 ohm
Load Cert Supply12 V, short-circuit proof. External load cell supply possible
Load Cell ConnectionAll strain gauge load cells; 6 or 4 wire connection
In-OutputAll I/O circuits fully galvanically isolated from sensor input and supply
Control InputsQuantity: 3, opto-isolated input, passive
Functions: zero setting, taring
Voltage: max. 30 VDC
Current: max. 10 mA
Control OutputsQuantity: 3 opto-isolated output, passive
Voltage: max. 30 VDC:
Current: max. 30 mA
Functions: Limits, weight status
Power Consumption6 W / 8 W (Versions /01, /04, /06, /07)
Supply Voltage24 VDC, ±20%
Dimensions(L × W × H)
Version 00: 3.9 × 4.6 × 1.77 in
(99 × 116 × 45 mm)
Versions 01, 04, 06, 07: 3.9 × 4.6 × 2.68 in (99 × 116 × 68 mm)
HousingHousing IP20 according to DIN 40050
Mounting on DIN Rail 35 mm according
to DIN 46277
Material: polyamide RoHS conform
  • Thumbnail of document M pr5220 ethernet transmitter 17542
    Download

    M pr5220 ethernet transmitter 17542

    Download

Request a Calibration Quote

We’re here to make calibration easy. Request a quote today and let our team give you the care, precision, and service you can trust.
Learn more

Browse By Brands

Uncover the brands that set the standard for quality and dependability in every industry we serve.
Learn more