Skip to main content
Press Enter
OMEGA

M12TX RTD Probe w/ 4 to 20mA Analog Output & M12 Connector

M12 Temperature Transmitter with 100Ω RTD

This product is no longer available. Contact us at 800-567-8686 for alternative solutions.

Have questions? We're here to help!
Have questions? We're here to help!

 The M12TX 100Ω RTD sensor with built-in transmitter can be programmable by a computer. The configuration kit required for programming is M12TX-CONFIGSET.  This unique probe is ideal for areas with space limitations where traditional head connections are too large to fit. The M12 thread design offers a secure industrial connection. The temperature Transmitter is designed with mineral insulated cable probe (MgO) which allows the probe to have a minimum bend radius of three times the diameter. 

• Programmable Transmitter 
• Molded Connector (IP67) 
• M12 Connection 
• 4 to 20 mA Output 
• -50 to 500°C  (-58 to 932°F)
Response TimeDiameter 3 mm <3.5 second, diameter 6 mm <13 second (test in water to IEC751- time for reaching 63.2% of instantaneous temperature change) three times the diameter.
Factory Setting0 to 150°C/sensor break >21 mA (upscale)
Sensor Error CompensationOver 2 points (maximum 1% of span)
Minimum Span50°C (122°F) [if the zero value is set between one of these values: -40°C (-40°F), -20°C (-4°F), 0°C (32°F), 20°C (68°F), 40°C (104°F), the minimum span is 20°C (68°F) rather than 50°C (122°F)]
Zero AdjustmentsAny value between -50 to 50°C
Range ConfigurationsIt is possible set the input temperature range (span) by the M12TX-CONFIG configuration kit (PC with OS Windows® required)
Supply Voltage InfluenceNegligible
Temperature Influence [Deviation from 20°C (68°F)]Maximum of ±0.3°C/25°C (77°F) or ±0.3% of span/25°C (77°F)
SensorClass A in accordance to IEC751
TransmitterMaximum of ±0.2°C or ±0.2% of span
Accuracy
Degree of ProtectionIP65 and IP67 in accordance to IEC60529
EMCIn accordance to EN 61326
Relative Humidity0 to 100%
Temperature-40 to 80°C (-40 to 176°F) for plastic body
Environment Conditions
Power Supply8.5 to 32 Vdc (polarity protected)
Isolation In-OutNon-isolated
Response Time (90%)<50 ms
Permissible Load700 @ 24 Vdc [RLo= (Vsupply-8.5)/0.020]
Signal4 to 20 mA
Output
Sensor Short-CircuitFixed to downscale (<3.6 mA) action
SelectableUpscale (>21.0 mA) or downscale (<3.6 mA) action
Sensor Break Monitoring
Tmax. Electronic80°C (176°F)
Range-50 to 500°C (-58 to 932°F)
SensorRTD Pt100 class A up to 300°C in accordance to IEC751
ConnectionM12x1 male in accordance to VDE0627 (output connection)
Probe Minimum Bending RadiusThree-times the outer diameter [except the sensing tip which length is 30 mm (1.2')]
Probe TypeCompact mineral insulated cable AISI 316L SS
BodyThermoplastic material