The Bipolar Isolation Amplifier IisPAQ-661 is used for isolation and conversion of bipolar and unipolar industrial standard signals.

The input and output range of IsoPAQ-661 can be easily set by using DIP switch. Due to the calibrated range selection no further adjustment is necessary.

A switchable compensation of the measuring range can be performed at the Zero/Span potentiometers on the front panel. Also the cut-off frequency can be adapted to the measurement task by using the DIP Switch.

The auxiliary power can be supplied via the connection terminals or via the optional In-Rail-Bus connector. A green LED on the front of the unit has been provided to monitor the power supply.

Calibrated signal setting via DIP switch
    Input and output range can be set by using DIP switch – high precision without any further adjustment
High bandwidth; short response time
    No signal distortion; no falsification of measured signal
Switchable Zero/Span compensation
    For readjustment of the sensor or field device
3-Port isolation
    Protection against erroneous measurements due to parasitic voltages or ground loops
Extremely slim design
    6.2 mm slim housing for a simple and space saving DIN rail mounting
Optional In-Rail-Bus mounting rail connector
    Allows for fast and economical installation
Protective Separation acc. to EN 61140
    Protects service personnel and downstream devices against impermissibly high voltage

LoadCurrent: ≤ 12 V (600 Ω vid 20 mA), Voltage: ≤ 5 mA (2 kΩ vid 10 V)
Linear Transmission RangeUnipolar: -1 - +110 %, Bipolar: -110 - +110 %
Residual Ripple< 10 mVrms
Transmission Error< 0.1 % full scale
Temperature Coefficient< 100 ppm/K
Zero/Span Compensation5% of measuring range
Cut-off Frequency (-3 dB)Current: 8 kHz, Voltage: 100 Hz
Response Time (T99)100 µs / 7 ms
Test Voltage3 kV AC, 50 Hz, 1 min. Input against output against power supply
Working Voltage (Basic Insulation)600 V AC/DC for overvoltage category II and pollution degree 2 acc. to EN 61010-1
Protection Against Electrical ShockProtective separation according to EN 61140 by reinforced insulation in accordance with EN 61010-1 up to 300 V AC/DC for overvoltage category II and pollution degree 2 between all circuits.
Ambient TemperatureOperation: -25 °C to + 70 °C (-13 to + 158 °F)
Transport and storage: -40 °C to + 85 °C (-40 to + 185 °F)
Power Supply24 V DC voltage range 16.8 V - 31.2 V DC, approx. 0.8 W
EMCEN 61326-1
Construction62 x 96.5 x 107 mm , protection class IP 20, mounting on 35 mm DIN rail acc. to EN 60715
WeightApprox. 70 g
Input Current (Calibrated Switchable)+/- 20 mA, 0 - 20 mA, 4 - 20 mA;
+/- 10 mA, 0 - 10 mA, 2 - 10 mA
Input Voltage (Calibrated Switchable)+/- 10 V, 0 - 10 V, 2 - 10 V
+/- 5 V, 0 - 5 V, 1 - 5 V
Input ResistanceCurrent: ≤ 25 Ω, Voltage: ≥ 1 MΩ
OverloadCurrent: < 50 mA, Voltage: < 30 V
Output Current (Calibrated Switchable)+/- 20 mA, 0 - 20 mA, 4 - 20 mA
+/- 10 mA, 0 - 10 mA, 2 - 10 mA
Output Voltage (Calibrated Switchable)+/- 10 V, 0 - 10 V, 2 - 10 V
+/- 5 V, 0 - 5 V, 1 - 5 V
  • Thumbnail of document Data sheet Iso PAQ 661 1742
    Download

    Data sheet Iso PAQ 661 1742

    Download
  • Thumbnail of document Iso PAQ 661 manual 1743
    Download

    Iso PAQ 661 manual 1743

    Download

Request a Calibration Quote

We’re here to make calibration easy. Request a quote today and let our team give you the care, precision, and service you can trust.
Learn more

Browse By Brands

Uncover the brands that set the standard for quality and dependability in every industry we serve.
Learn more