The HC2-SH fulfills the highest demands on measuring accuracy. It measures humidity and temperature and calculates the dew/frost point.

Applications
HVAC, food industry, building services equipment, paper, textile, pharmaceutical industries, HVAC, food industry, building services equipment, paper, textile, pharmaceutical industries, and meteorological (HC2-S3H)

• Accuracy: ±0.5 %rh, ±0.1 K, at 23 °C ±5 K
• Range of application: -50…100 °C / 0…100 %rh
• Digital interface (UART) and scalable analog outputs, 0…1 V
• Standard output scaling: 0…1 V = -40…60 °C / 0…100 %rh
• Adjusted at 23 °C and 10, 20, 30, 40, 50, 60, 70, 80, 90 %rh, then calibrated at 20, 50, 80 %rh

Probe typeStandard black probe
Operating range-50…100 °C / 0…100 %rh
Accuracy at 23 ±5 °C±0.5 %rh / ±0.1 K
Accuracy w. adjustment profile "High Precision"At 23 °C / 10, 20, 30, 40, 50, 60, 70, 80, 90 %rh ± 0.5 %rh / 0.1 K
Power supply / Power consumption 3.2…5 VDC ±0 % / < 4.5 mA
Long-term stability<1 %rh / year
Humidity sensorHygromer IN-1
Temperature sensorPT100 1/3 DIN Class B
Probe protectionPolycarbonate plastic cage, black
Filter cartridgePolyethylene dust filter, gray, 20 um
Response time t 63<15 sec.
Allowed wind speed20 m/s, with filter
Psychrometric calculationsDew or frost point
Reproducibility Airchip<0.02 %rh / 0.01 K
Exploitation softwareROTRONIC HW4
Probe Adjustment by Software1 Point & multipoint %rh & °C
Firmware UpdateWith internet and HW4 software
User InformationFrom Software HW4 (device manager)
Data Processing Via HW4With interface cables
Device Protected PasswordYes
Type of Output Signals2 x 0…1 VDC
Analog Outputs Scaleable by UserYes
Analog Output Signal (Standard)UART
Service InterfaceUART
Reverse Voltage ProtectionMechanically in the connector
Max. Cable LengthUp to 5 m with passive cable. Up to 100 m with active cable.
Enclosure MaterialPolycarbonate
FDA/GAMP CompatibilityFDA 21 CFR Part 11 and GAMP compatible
DimensionsØ15 x 83 mm
Weight10 g