GPR-3100 Oxygen Analyzer

Temperature controlled sample handing system providing isothermal environment for the sample for increased accuracy

This product is no longer available. Contact us at 800-567-8686 for alternative solutions.

Have questions? We're here to help!
Have questions? We're here to help!

High-accuracy oxygen analyzer for monitoring gas in industrial processes where trace oxygen from low parts per million to pure O2 has to be precisely measured. Utilizing AII’s high performance galvanic oxygen sensors these advanced instruments are simple to use with a common, across-the-range chassis, HMI and menu structure, so an operator only needs to learn operation of just one instrument for multiple gas analysis applications at various oxygen levels. Available as bench-, 19" rack-, panel- and wall-mounted for flexible installation.

• Easy to use HMI
• High accuracy ( ±0.02 ppm in lowest range)
• Four measurement ranges with manual or auto-ranging
• 24 month sensor life with normal usage
• Sample in CO2 backgrounds with XLT sensor
• Bench, rack or wall mounting options
• Two Alarms
• Integrated bypass valve (for GPR-1600)
• Easy access and sensor replacement
• Easy to use HMI

Response TimeT90 < 13 seconds
Sensitivity (LDL)0.1% oxygen
Linearity< 0.5% of scale
Sensor ModelGPR-11-120-OP
Sensor Life at 25°C (77°F) and 1 Atmosphere24 months in 100% oxygen
Calibration IntervalTypically: 1-3 months
Inlet Pressure248 bar g (3600psig)
Flow Rate0.5 - 1.0 l/m (1-2 SCFH)
Gas Connections1/4" compression tube fittings
DisplayGraphical LCD 12.7 x 7cm (5 x 2.75"); resolution 0.01
EnclosurePainted aluminum
See individual mounting options for dimensions
CompensationBarometric pressure and temperature;
Temperature controlled sample system and sensor (GPR-3100 only)
Analog Output4-20 mA isolated, 0-1V, and 0-5V
Range ID1-5 V or 4-20mA, optional relay contacts
CommunicationsChoose from RS485, RS232 or USB
AlarmsTwo user-adjustable alarm relays
Operating TemperatureGPR sensor: 5°C to 45°C (41°F to 113°F)
XLT sensor: -10°C to 45°C (14°F to 113°F)
PowerUniversal 100-240 V AC
Measurement Range0-100%, plus suppressed zero ranges.
50, 80, or 90-100%
Accuracy< ±2% of range
±0.1% at constant conditions after calibration with 95-100% oxygen (GPR-3100)
  • Thumbnail of document GPR 3100 Data Sheet 10094
    Download

    GPR 3100 Data Sheet 10094

    Download

Request a Service Quote

Get a customized quote for calibration, validation, repair, or training services designed to keep your instruments accurate and compliant.
Learn more