GPR-1800 Oxygen Analyzer

IS trace oxygen analyzer designed for use in process environments where the low detection limit down the AII's industrial oxygen sensors can be well utilized

This product is no longer available. Contact us at 800-567-8686 for alternative solutions.

Have questions? We're here to help!
Have questions? We're here to help!

The GPR-1800 series of intrinsically safe trace oxygen analyzers are designed for use in demanding process environments where the low detection limit down the AII’s industrial oxygen sensors can be well utilized. Typical for Analytical Industries gas analyzers, they are simple to use as well as easy and cost-effective to maintain thanks to the use of their maintenance-free galvanic oxygen sensors. The innovative liquid drain manifold, which is available as an option, protects and extends the sensor's life span in processes where liquids may be present in the sample gas.

• Four measurement ranges provided
• LDL of 50 ppb
• Measures in CO2 with XLT sensor
• Sensor life of up to 24 months
• Simple, intuitive HMI
• Barometric pressure and temperature compensation
• Two user configurable alarms
• Optional Modbus
• Range of sampling options available

EnclosureUL: NEMA Type 3R
ATEX: NEMA 4x
CompensationGPR-1800 IS: Temperature
GPR-1800 AIS:Barometric pressure and temperature
Signal OutputGPR-1800 IS: 4-20mA Loop current
GPR-1800 AIS: 4-20 mA or 1-5V
CommunicationsGPR-1800 AIS:Optional Modbus RTU (AIS 24 V version only)
AlarmsGPR-1800 AIS:Two user configurable alarms: magnetic coil relays rated 3A at 100 VAC
Operating TemperatureGPR sensor: 5°C to 45°C (41°F to 113°F)
XLT sensor: -10° to 45°C (14°F to 113°F)
PowerGPR-1800 IS: 18-24 V DC 2wire loop power
GPR-1800 AIS: 12-28 V DC or 110-220 V AC
Liquid DrainLiquid Drain option available for both models
ApprovalsCULUS: Class I, Division 1, Groups C & D
Tamb -20° to +50°C
ATEX: II 2 G
Ex d [ib] ib IIB T4 Gb
Measurement Range0-10, 0-100, 0-1000 ppm, 0-1%,
0-25% (for calibration only)
Accuracy< 2% of selected range at constant conditions
Response TimeT90 < 10 seconds
T90 < 2 minutes (for Liquid drain models)
Sensitivity (LDL)0.05ppm
Linearity<1% of scale
Sensor ModelGPR-12-333 or GPR-12-333-LD
XLT-12-333 or XLT-12-333-LD for gases containing > 0.5% CO2
Sensor Life at 25ºC (77°F) and 1 Atm24 months in < 1000 ppm O2 5°C (77°F)and 1 atm
Calibration Interval30 days
Inlet Pressure0.34-2 barg (5-30 psig) with atmospheric vent
Flow Rate0.5-1.0 l/m (1-2 SCFH)
Gas Connections1/8" compression tube fittings
1/4" compression tube fittings (with liquid drain option)
Wetted PartsStainless steel
DisplayGraphical LCD 7 x 3.5cm (2.75 x 1.375"); resolution 0.01 ppm
  • Thumbnail of document GPR 1800 AIS Manual 10110
    Download

    GPR 1800 AIS Manual 10110

    Download
  • Thumbnail of document GPR 1800 IS Manual 10111
    Download

    GPR 1800 IS Manual 10111

    Download
  • Thumbnail of document GPR 1800 Data Sheet 10108
    Download

    GPR 1800 Data Sheet 10108

    Download
  • Thumbnail of document GPR 1800 AIS LD Manual 10109
    Download

    GPR 1800 AIS LD Manual 10109

    Download

Request a Service Quote

Get a customized quote for calibration, validation, repair, or training services designed to keep your instruments accurate and compliant.
Learn more