Skip to main content
Press Enter
Starting at $652.03USD
Configure
Dwyer

EPTA Electro-pneumatic Transducers

Convert an analog input signal to a linearly proportionate pneumatic output by modulating its control valves to regulate branch line pressure to the set point determined by the input signal

Starting at
$652.03USD
Have questions? We're here to help!
Have questions? We're here to help!
Configure

 The Series EPTA Electro-Pneumatic Transducers convert an analog input signal to a linearly proportionate pneumatic output by modulating its control valves to regulate branch line pressure to the set point determined by the input signal. All models incorporate two low voltage valves, an integral in-barb filter, a 0 to 30 psi analog gage, an anodized aluminum manifold, and brass barbed fittings. The EPTA offers adjustable span and offset as well as manual override. This unit has no air consumption and is immune to mounting orientation. Output pressure ranges include field-selectable 0 to 10, 0 to 15, and 0 to 20 psig. Also included is an analog 0 to 5 VDC feedback signal indicating the resultant branch line pressure. Universal 24 VAC/24 VDC supply voltage and field-selectable 4 to 20 mA, 0 to 5 VDC, 0 to 10 VDC, or 0 to 15 VDC inputs ensure single unit compatibility with most systems. The standard models maintain branch pressure on power loss while the Fail-Safe models will drop the branch pressure to 0 psi on power loss. Mounting configurations include a metal bracket mount in the EPTA-B models and a snap-track mount in the EPTA-S models. The A-400 accessory kit will allow the EPTA-S models to be mounted on a standard DIN rail.

• Adjustable span and offset
• Manual override
• Field selectable output ranges
• Not position sensitive
ServiceClean dry air or any inert gas.
Input SignalDC Current (4-20 mA) or DC Voltage (0-5/0-10/0-15).
Input ImpedanceCurrent: 250 ohms; Voltage: Infinite.
Output SignalJumper selectable 0-10 psig (0-69 kPa), 0-15 psig (0-103 kPa), or 0-20 psig (0-138 kPa).
Feedback Output0 to 5 VDC.
Air Supply25 psig (172 kPa) maximum.
Air Flow750 scim.
Air Consumption0 scim normal operation, Fail-Safe model vents to 0 psi on power loss.
Accuracy±1.0% full scale @ room temperature; ±2.0% full scale @ 32 to 120°F (0 to 48.8°C).
Supply Voltage24 VDC (+10%/-5%) or 24 VAC (±10%) 50/60 Hz
Supply Current180 mA maximum, 200 mA maximum on Fail-Safe model.
Temperature LimitsOperating: 32 to 120°F (0 to 48.8°C); Storage: -20 to 150°F (-6.7 to 65.6°C).
Operating Humidity Range5 to 95%, non-condensing.
Pressure Connections1/4" O.D. (polyethylene tubing optimum).
Electrical ConnectionsPlug-in block terminal type with 5 mm pin spacing.
Wire SizeUp to one 14 AWG per terminal.
WeightEPTA-S0: 6.9 oz. (196 g), EPTA-S1: 9.2 oz. (261 g), EPTA-B: 14.5 oz. (411 g).

 • Operation of valve actuators, positioners, damper and louver actuators.

Accessories

Request a Service Quote

Get a customized quote for calibration, validation, repair, or training services designed to keep your instruments accurate and compliant.
Learn more

Browse By Brands

Uncover the brands that set the standard for quality and dependability in every industry we serve.
Learn more