EE871 CO2 Probe
Modbus RTU interface, dual wavelength NDIR principle, measuring range up to 5% CO2 (50,000 ppm)
This product is no longer available. Contact us at 800-567-8686 for alternative solutions.
The EE871 operates on the dual wavelength NDIR principle, which compensates for ageing effects, is highly insensitive to pollution and stands for outstanding long-term stability even in demanding environment. A multiple point CO2 and temperature adjustment procedure leads to excellent CO2 measurement accuracy over the entire temperature working range, ideal for use in agriculture or outdoors for instance. The measured data range of up to 5% CO2 (50,000 ppm) is available on E2 digital interface and up to 1% CO2 (10,000 ppm) is available on Modbus RTU interface. An optional kit facilitates easy configuration and adjustment of EE871. The measurement interval can be set according to the application requirements, by this the average current consumption can be reduced to 120 μA for battery-operated devices.
• Auto-calibration
• Outstanding long-term stability
• Temperature compensation
• Very low current consumption
• IP65 enclosure
• Modbus RTU or E2 interface
• Greenhouses and livestock barns
• Fruit and vegetable storage
• Hatchers and incubators
• Outdoor CO2 monitoring
• Data loggers and handhelds