Skip to main content
Press Enter
OMEGA

DRSL-SP3 DIN Rail Isolated Repeater/Splitter for Bipolar Process Signals

Bipolar Isolated DIN Rail Signal Conditioner/Splitter for Process Signals

Normally ships in
2-3 weeks
Have questions? We're here to help!
Have questions? We're here to help!

 Supported Applications

The Omega DRSL-SP3 is a bipolar isolated DIN rail signal conditioner and splitter designed for process signals. It provides galvanic isolation and converts bipolar process voltage or current signals for transmission to SCADA or PLC systems.

Operating Conditions & Performance

The series operates within an ambient temperature range of -25 to 70°C (-13 to 158°F) with a storage capability from -40 to 85°C (-40 to 185°F). It functions in relative humidity conditions of 0 to 95% RH non-condensing and carries an IP20 protection degree. The device is rated for Pollution Degree 2 and Measurement/Overvoltage Category II.

Performance specifications include a response time of <7 ms or <44 ms (0 to 100%) depending on configuration, with high accuracy of ≤±0.05% of span. The temperature coefficient is specified as ≤±0.01% of span/°C. Isolation between input/output 1/output 2/supply features a working voltage of 300 Vac and a test isolation voltage of 2.5 kVac.

Configuration Options

The DRSL-SP3 series supports configurable measurement ranges via DIP switches for both current and voltage inputs, with two isolated outputs available per unit.

• Input Ranges: Programmable bipolar current ranges of ±10 mA or ±20 mA (functional range -23 to 23 mA) and programmable bipolar voltage ranges of ±5V or ±10V (functional range -11.5 to 11.5V).
• Output Signals: Configurable current outputs include 0 to 20 mA, 4 to 20 mA, ±10 mA, and ±20 mA; voltage outputs include 0 to 10V, 2 to 10V, 0 to 5V, 1 to 5V, and 0 to 11.5V.
• Load Requirements: Current output supports a maximum load of 300 Ω per channel at 23 mA; voltage output requires a minimum load resistance of >10 kΩ.
• Power Supply: Operates on 16.8 to 31.2 Vdc via Power Rail or connectors, with maximum power consumption of 0.8 W.

The unit features a slimline housing measuring 113 H x 6.1 W x 115 mm D (4.4 x 0.24 x 4.5") and weighs approximately 70 g (0.15 lb). It mounts to DIN rail using screw terminals.

Key Product Differences

The primary model in this series is the DRSL-SP3, described as a bipolar isolated signal conditioner/splitter for process signals. The device includes selectable cut-off frequencies of >100 Hz or 10 Hz via DIP-switch.

Available accessories to support installation include:

• DRSL-PWR-RAIL: Power rail with cover and end covers, 1 m (3.3') length.
• DRSL-PCU: Power connector unit providing 24 Vdc/2.5 A output to the power rail.
• DRSL-MOD-STOP: Module stop screwed onto the power rail to support and hold mounted devices.

The product is sold separately from the power rail (DRSL-PWR-RAIL). The series holds CE, UL US, and RoHS certifications with a 1 YEAR WARRANTY.

• Isolation and Conversion of Bipolar Process Voltage and Current Signals to Unipolar/Bipolar Signals
• Splitter Function: 1 Process Input, 2 Process Outputs
• Slimline Housing—Only 6 mm (0.24') Wide
• Multiple Signal Ranges (DIP-Switch Selectable)
ApprovalsCE, UL, RoHS
Bandwidth100 Hz or 10 Hz (selectable via DIP-switch)
Calibration Temperature, Max28 °C
Calibration Temperature, Min20 °C
Electrical Output0 to 23 mA
EMC Immunity NoteExtended EMC Immunity NAMUR NE 21, A Criterion, Burst: <±1% of span
Enclosure RatingsIP20
Height113 mm
InstallationPollution degree 2 and measurement/overvoltage category II
IsolationIsolation: Input/output 1/output 2/supply;Isolation Voltage (Test): 2.5 kVac;Isolation Voltage (Working):300 Vac
Length115 mm
MountingDIN Rail 35 mm Standard, EN 60715
MTBF187 yrs
Noise Calibration>60 dB
Operating Temperature, Max70 °C
Operating Temperature, Min-25 °C
Power Consumption0.8 W, Internal - max 0.65 W
Relative Humidity0 to 95% RH (non-condensing)
Screw Terminal Torque0.5 Nm
Series IDDRSL-SP3-Rptr-Spltr-BP
Span, MaxCorresponds to the presently selected DIP switch output range
StabilityLoad Stability: ≤0.002% of span/100 Ω
Storage Temperature, Max85 °C
Storage Temperature, Min-40 °C
Supply Power TypeDC
Voltage Loss<1 V
Weight70 g
Width6.1 mm
Wire Gauge26 to 12 AWG

Request a Calibration Quote

We’re here to make calibration easy. Request a quote today and let our team give you the care, precision, and service you can trust.
Learn more

Browse By Brands

Uncover the brands that set the standard for quality and dependability in every industry we serve.
Learn more