Skip to main content
Press Enter
OMEGA

DRSL-SP2 DIN Rail Isolated Repeater/Splitter for Process Signals

Isolated DIN Rail Signal Conditioner/Splitter for Process Signals

Have questions? We're here to help!
Have questions? We're here to help!

 The DRSL-SP2 isolated signal conditioner/splitter provides a competitive choice in terms of both price and technology for galvanic isolation of process voltage or current signals to SCADA systems or PLC equipment. Two process outputs are provided which mirror the single process input.

 
The DRSL-SP2 can be used for signal conversion of standard process voltage or current signals into two individual analog signals. The unit offers 4-port isolation, provides surge suppression and protects control systems from transients and noise. The DRSL-SP2 also eliminates ground loops and can be used for measuring floating signals. Low power consumption facilitates DIN rail mounting without the need for any air gap. Factory calibrated measurement ranges are easily configured via DIP switches. When the input is configured for 2-wire transmitter mode, the DRSL-SP2 provides the current loop supply voltage. The unit operates over a wide temperature range from -25 to 70°C (-13 to 158°F).
 
• Isolation and Conversion of Process Voltage or Current Signals
• Splitter Function: 1 Process Input–2 Process Outputs
• Power Supply and Signal Isolator for 2-Wire Transmitter
• Slimline Housing–Only 6 mm (0.24') Wide
Screw Terminal Torque0.5 Nm
Wire Size0.13 x 2.5 mm2/AWG 26 to 12 stranded wire
DIN Rail TypeDIN EN 60715 - 35 mm
Weight70 g (0.15 lb) approx
Dimensions113 H x 6.1 W x 115 mm D (4.4 x 0.24 x 4.5")
Mechanical
Installation AreaPollution degree 2 and measurement/overvoltage category II
Protection DegreeIP20
Relative Humidity0 to 95% RH non-condensing
Calibration Temperature20 to 28°C (68 to 82°F)
Storage Temperature-40 to 85°C (-40 to 185°F)
Operating Temperature-25 to 70°C (-13 to 158°F)
Environmental
NAMUR NE 21, A Criterion, Burst<±1% of span
Extended EMC Immunity
EMC Immunity Influence<±0.5% of span
Programmable Signal Ranges0 to 10, 2 to 10, 0 to 5 and 1 to 5V
Signal Range0 to 10V
Voltage Output
Current Limit≤28 mA
Load Stability≤0.01% of span/100 Ω
Load23 mA/300 Ω max
Programmable Signal Ranges0 to 20 mA and 4 to 20 mA
Signal Range0 to 20.5 mA (span)
Current Output
No. of Outputs2
Output
Input Resistance≥500 kΩ
Programmable Measurement Ranges0 to 5V, 1 to 5V, 0 to 10V, 2 to 10V
Functional Range0 to 11.5V/ 0 to 5.75V
Measurement Range0 to 10.25V
Voltage Input
2-Wire Transmitter Supply>17V/20 mA
Input Voltage Drop<1.5V
Programmable Measurement Ranges0 to 20 mA and 4 to 20 mA
Functional Range0 to 23 mA
Measurement Range0 to 20.5 mA
Current Input
Input
Temperature Coefficient<±0.01% of span/°C
Accuracy<±0.05 % of span
SpanCorresponds to the presently selected DIP switch output range
Response Time (0 to 90%, 100 to 10%)<7 ms
Signal/Noise Ratio>60 dB
Isolation Voltage (Working)300 Vac
Isolation Voltage (Test)2.5 kVac
IsolationInput/output 1/output 2/ supply
Internal Consumption0.4 W typical/0.65 W max
Power Consumption1.2 W max
Supply Voltage (via Power Rail or Connectors)16.8 to 31.2 Vdc
General
Load>10 kΩ min

Request a Calibration Quote

We’re here to make calibration easy. Request a quote today and let our team give you the care, precision, and service you can trust.
Learn more

Browse By Brands

Uncover the brands that set the standard for quality and dependability in every industry we serve.
Learn more