Skip to main content
Press Enter
OMEGA

CT7310-D Economical 2 Channel Circular Process Recorder

Economical 2-Pen Circular Process Recorder

Normally ships in
2-3 weeks
Have questions? We're here to help!
Have questions? We're here to help!
Configure

Supported Applications

The Omega CT7300 Series is an economical, microprocessor-based circular process recorder designed to measure and record up to two process variables on a standard 10-inch (254 mm) chart. The series supports recording applications requiring inputs from thermocouples (Types J, K, T, R, B, S), RTDs (Pt100 DIN), or linear signals including 4-20 mA and 0-5 Vdc.

Operating Conditions & Performance

The CT7300 Series operates within an ambient temperature range of 0 to 60°C (32 to 140°F) with a humidity rating of 0 to 90% RH non-condensing. Storage temperatures are rated from -40 to 65°C (-40 to 149°F). The unit is powered by 110/220 Vac, 50/60 Hz and includes battery backup for up to 48 hours of recording during power loss.

Performance specifications include a recording accuracy of ±0.5% of span (for a 100-division span) and cold junction accuracy of ±0.2°C/°F @ 25°C (77°F). Ambient error is specified as ±0.01% span/°C from 25°C ambient. The full-scale pen response time to sensor break is less than 10 seconds.

Input ranges supported by the series include:

• Type J: -130°C to 760°C (-202°F to 1400°F)
• Type K: -130°C to 1370°C (-202°F to 2498°F)
• Type T: -200°C to 400°C (-328°F to 752°F)
• Type B: 100°C to 1824°C (212°F to 3315°F)
• Type R: 0°C to 1650°C (32°F to 3002°F)
• Type S: 0°C to 1640°C (32°F to 3000°F)
• Pt100 (DIN): -210°C to 440°C (-346°F to 824°F)
• Linear: 4 to 20 mA and 0 to 5 Vdc

Configuration Options

The series is available in three primary configurations based on alarm relay integration:

• CT7310: Dual Pen Recorder without alarms.
• CT7311: Dual Pen Recorder with Alarm Relay for Pen 1.
• CT7312: Dual Pen Recorder with Alarm Relays for both Pen 1 and Pen 2.

Housing options include a standard NEMA 12X enclosure or an optional NEMA 4 (IP65) rated case, specified by adding "-NEMA" to the model number. An optional LED display indication is available for models with the suffix "-D".

Alarm relays are programmable for process, band, non-latching, or latching operation. The relay output is DPDT, 1.0 A @ 120 Vac resistive, with hysteresis set at 2 units and safe-sided activation. Error protection includes de-energization during sensor break.

Additional features include built-in chart lights for visibility in low-light conditions and a magnetic hub for easy paper replacement. The unit dimensions are 356 H x 356 W x 97 mm D (14 x 14 x 4") with a weight of 3 kg (7 lb).

Key Product Differences

The CT7300 Series distinguishes itself through configurable alarm capabilities and enclosure ratings. The base model, CT7310, provides dual-pen recording without relay outputs. Models CT7311 and CT7312 add programmable DPDT relays for one or two channels respectively.

Enclosure variations allow selection between the standard NEMA 12X rating and a more robust NEMA 4 (IP65) option, which is added to the model number as "-NEMA". The optional LED display suffix "-D" provides digital indication alongside the analog chart recording.

Replacement parts include red pens (P/N CT7300-RED), green pens (P/N CT7300-GREEN), and standard circular charts (P/N CT7000C series). Custom range paper is available via P/N CT7000C-CUSTOM.

• Universal Input
• 2 Pen Circular Process Recorder, 254 mm (10' Chart)
• Quick, Easy Setup
• Easy-to-Replace Paper Chart with Magnetic Hub
Accuracy± 0.5 %
Accuracy DetailChart Recording: ±0.5% of span (100-division span)
Alarm modesActive High Output, Active Low Output, Adjustable, Band, High/Low, Manual reset
ApprovalsCE
Battery life48 hr
Battery Size and TypeAlkaline 9V
Chart Diameter254 mm
Chart SpeedConfigurable—4, 8, 12, 24, 48 and 168 hours of rotation
CMRR>120 dB @ 60 Hz
Current Measurement Range4 to 20 mA
Cutout Dimensions323 x 323 mm
DeadbandSet at 2 units; activation is safe-sided
Height356 mm
Input NoteInput Filtering: Up to 120 sec;Input Isolation: PV inputs isolated from all alarm outputs
Length97 mm
Measurement Range NoteThermocouple: J: -130 to 760°C, K: -130 to 1370°C, T: -200 to 400°C, R: 0 to 1650°C, S: 0 to1649°C, B: 100 to 1824°C RTD: -210 to 440°C Current: 4 to 20 mA Voltage: 0 to 5 Vdc
Measurement TypeThermocouple, RTD, Current, Voltage
MountingVertical Mount (±20 Degrees), Horizontal Mount (±10 Degrees)
Mounting Orientation± 20 degrees of vertical, ± 10 degrees of horizontal
Number of Channels2
Operating Temperature, Max60 °C
Operating Temperature, Min0 °C
Pen TypeInk Style
Power Consumption15 VA
Relative Humidity0 to 90% RH, non-condensing
RTD Type100 Ω Pt Sensor
Sensor Break DetectionError Protection: De-Energized During Sensor Break; Sensor Break: <10 sec
Series IDCT7300-Series
Standard Limits of ErrorError Limit: Cold-Junction Compensation Error: ±0.2°C/°F @ 25°C, Ambient Temperature Error Limit: 0.01% of span per °C
Storage Temperature, Max65 °C
Storage Temperature, Min-40 °C
Supply Power Note110/220 Vac, 50/60 Hz
Supply Power TypeAC
Supply Voltage110/220 Vac
Switch Rating1 A @ 120 Vac
Switch Rating NoteDPDT, 1.0 A @ 120 Vac resistive
Switch TypeDPDT
Temperature Measurement RangeJ: -130 to 760°C, K: -130 to 1370°C, T: -200 to 400°C, R: 0 to 1650°C, S: 0 to1649°C, B: 100 to 1824°C, RTD: -210 to 440°C
Thermocouple TypeJ, K,T, R, S, B
Vibration0.3 to 100 Hz @ 0.2 g
Voltage Measurement Range0 to 5 Vdc
Weight3 kg
Width356 mm
Wire Code Option3- Wire
  • Download

    CT7310 CT7311 CT7312 19047

    Download

Request a Calibration Quote

We’re here to make calibration easy. Request a quote today and let our team give you the care, precision, and service you can trust.
Learn more

Browse By Brands

Uncover the brands that set the standard for quality and dependability in every industry we serve.
Learn more