 OMEGA’s new hot point® calibrators allow calibration of thermocouple and RTD probes quickly and easily with accuracy to 0.9°C (1.5°F). An integral RTD sensor assures high measurement accuracy and repeatability. A built-in microprocessor-based PID digital controller assures exceptional stability. Setpoint and actual temperature are displayed simultaneously. Temperature can be set in one-degree increments from 22°C (40°F) above ambient to 482°C (900°F).

 
The CL900 calibrator accepts a variety of standard and metric optional inserts which are available in 4" and 6" depths and for probe diameters from 1/8" to 3/8". An undrilled insert is also available. The CL900 comes complete with a 1/4" diameter, 6" deep insert well and insert block tongs. Additional inserts can be ordered separately as required for other diameter probes. 6" depth inserts are used for probes 7" and longer; 4" depth inserts are used for probes 5" and longer.
 
The CL950 calibrator features a built-in well with 5 ports sized to accommodate a 1/16", 1/8", 3/16", and two 1/4" diameter probes. The multi-port design allows for the use of a calibrated or NIST-traceable probe and meter to be used as a standard while calibrating other probes. The 5 port design also allows for calibration of more than one probe at a time, and eliminates the need for separate insert wells.
• Calibrates Thermocouples and RTD’s in Seconds 
• Highly Accurate 0.9°C (1.5°F) and Exceptional Stability (0.3°F) for Precision Calibrations 
• Completely Portable for Factory, Laboratory and Instrument Shops 
• Interchangeable Test Wells and CL950 BuiltIn 5 Port Well Design Provides Customer Flexibility 
• Wide Temperature Range 40°F Above Ambient to 900°F (482°C) Covers Most Industrial Applications 
• NIST Calibration Available
Temperature RangeAmbient +22 to 482°C (+40 to 900°F)
Operating Ambient Temperature Range5°C to 38°C (40°F to 100°F)
Accuracy (1°F resolution)CL900 with 6" test well inserts: ±1.5°F ±1 LSD.
CL900 with 4" test well inserts: ±3°F ±1 LSD.
CL950: ±1.5°F, ±1 LSD.
Control Stability±0.3°F or better
Temperature Uniformity (within the bottom 1" of the test well)CL900:
with 6" test well inserts: 0.3%
with 4" test well inserts: ±0.4%.
CL950: ±0.3%
Max. Probe ImmersionCL900:
with 6" test well inserts: 150 mm (6")
with 4" test well inserts: 100 mm (4").
CL950: 150 mm (6")
ControlMicroprocessor-based PID digital controller with data retention
Power110-125 Vac, 50/60 Hz, 1050 watts; 220 Vac, 50/60 Hz, 1050 watts
Dimensions300 H x 216 W x 311 mm D (11.75 x 8.5 x 12.25")
Weight10.1 kg (22.3 lb)