BLM Magnetostrictive Sensor

For bypass level indicators, continuous level measurement on the outside of the bypass

Have questions? We're here to help!
Have questions? We're here to help!

Level sensors with a magnetostrictive, high-resolution measuring principle are used for continuous level measurement of liquids and are based on determining the position of a magnetic float following the magnetostrictive measuring principle. The sensors are mounted on the outside of a bypass level indicator.

The measuring process is triggered by a current impulse. This current produces a circular magnetic field along a wire made of magnetostrictive material, which is held under tension inside the sensor tube. At the point being measured (liquid level) there is a cylindrical float with permanent magnets acting as a position transducer, whose field lines run at right angles to the impulse magnetic field. This magnetic field of the float tensions the wire.

The superposition of these two magnetic fields triggers a mechanical wave in the wire. This is converted into an electrical signal at the end of the wire in the sensor housing by a piezoceramic pick-up.

By measuring the elapsed transit time, it is possible to determine the start point of the torsional stress wave and therefore the float position with a high degree of accuracy.

 


 

• Continuous level measurement on the outside of the bypass
• 2-wire technology 4-20 mA
• Measured value output via digital interface and a selectable measured value as analogue signal
• Case from stainless steel (display from glass)
• Magnetostrictive level measuring instrument with high resolution

Connection Housing (Sensor Housing)Stainless steel 1.4404
Version with or without display, with
window
Sensor TubeStainless steel 1.4571, tube Ø 12 mm,
tube length L max. 5,800 mm
Temperature RangeMedium temperature: -60 to +185 °C
Ambient temperature:
- Version without display: -40 to +85 °C
- Version with display: -20 to +70 °C
- Version Ex i: T3/T4/T5/T6 -20 °C to +70/+70/+70/+60 °C
- Version Ex d: T3/T4/T5/T6 -40 °C to +70/+70/+70/+60 °C
Output Signal4-20 mA, HART®
Power SupplyDC 10 ... 30 V
Measuring Accuracy< ±0.5 mm
Resolution< 0.1 mm
LoadMax. 900 Ω at 30 V
Mounting PositionVertical ±30°
Ingress ProtectionIP 67
• Transmitters for the continuous level measurement of liquids in bypass level indicators
• Chemical and petrochemical industries, offshore
• Shipbuilding, machine building
• Power generating equipment, power plants
• Pharmaceutical, food, water treatment, environmental engineering industries
  • Thumbnail of document DS LM1005 en co 59794 15452
    Download

    DS LM1005 en co 59794 15452

    Download
  • Thumbnail of document OI FLM BLM FFG P BP de en ks 86582 15453
    Download

    OI FLM BLM FFG P BP de en ks 86582 15453

    Download

Request a Calibration Quote

We’re here to make calibration easy. Request a quote today and let our team give you the care, precision, and service you can trust.
Learn more

Browse By Brands

Uncover the brands that set the standard for quality and dependability in every industry we serve.
Learn more