Skip to main content
Press Enter
Fluke

568 EX/ITL Intrinsically Safe Infrared Thermometer

Take intrinsically safe temperature measurements in hazardous environments anywhere in the world

Have questions? We're here to help!
Have questions? We're here to help!

The Fluke 568 Ex Intrinsically Safe Infrared Thermometer is certified by major rating bodies for use in Class I Div. 1 and Div. 2 or Zone 1 and 2 hazardous environments anywhere in the world. Whether you work in petroleum, chemical, oil and gas, or pharmaceutical environments, the 568 Ex allows you to carry the most trusted name in test tools into most Ex-rated areas around the globe. The simple, three-button on-screen menu interface is quick to use and makes even complex measurements easy. It takes just a few pushes of a button to adjust emissivity, record data, or turn on and off alarms. The 50:1 distance-to-spot ratio allows you to measure smaller objects from further away. And it also is compatible with K-type probes for contact measurements. Either way, you can count on the rugged, ergonomic design to stand up to tough conditions.

• Intrinsically safe infrared and contact thermometer
• Meets intrinsically safe certifications in Class I Div. 1 and Div. 2 or Zone 1 and 2 hazardous environments
• Measures temperatures from -40°C to 800°C (-40°F to 1472°F)
• Comes with a conductive case to safely carry the IR thermometer into hazardous areas
• Offers a distance-to-spot ratio of 50:1
Infrared temperature range -40°C to 800°C (-40°F to 1472°F)
Infrared accuracy < 0°C (32°F): ±(1.0°C (±2.0°F) + 0.1°/1°C or°F);
> 0°C (32°F): ±1% or ±1.0°C (±2.0°F), whichever is greater
Display resolution 0.1°C / 0.1°F
Infrared spectral response 8 µm to 14 µm
Infrared response time < 500 ms
Thermocouple type-k input temperature range -270°C to 1372°C (-454°F to 2501°F)
Thermocouple type-k input accuracy < -40°C: ±(1°C + 0.2°/1°C)
≥ -40°C: ±1% or 1°C, whichever is greater < -40°F: ±(2°F + 0.2°/1°F)
≥ -40°F: ±1% or 2°F, whichever is greater
Laser sighting Single-point laser
Minimum spot size 19 mm (0.75 in)
Emissivity adjustment By built-in table of common materials or digitally adjustable from 0.10 to 1.00 by 0.01
Data storage 99 points
Hi/Low alarms Audible and two-color visual
Min/Max/Avg/Dif Yes
Display Dot matrix with function menus
Backlight Two levels, normal and extra bright for darker environments
Trigger lock Yes
Switchable celsius and fahrenheit Yes
Power 2 AAA/LR03 type-approved batteries (For a list of type-approved batteries, refer to Product Safety Instructions.)
Battery life 4 hours with laser and backlight on;
100 hours with laser and backlight off, at 100% duty cycle
D:S (distance to measurement spot size) 50:1
Operating temperature 0°C to 50°C (32°F to 122°F)
Storage temperature -20°C to 60°C (-40°F to 140°F)
Bead thermocouple type-k range -40°C to 260°C (-40°F to 500°F)
Bead thermocouple type-k accuracy ±1.1°C (2.0°F) from 0°C to 260°C (32 °F to 500°F),
typically within 1.1°C (2.0°F) from -40°C to 0°C (-40°F to 32°F)


 

 

Accessories

Request a Calibration Quote

We’re here to make calibration easy. Request a quote today and let our team give you the care, precision, and service you can trust.
Learn more

Browse By Brands

Uncover the brands that set the standard for quality and dependability in every industry we serve.
Learn more