5616 Secondary Reference Platinum Resistance Thermometer
High-purity platinum element and durability make it great for calibrating in the factory, field or lab
The 5616-12 is a 100 Ω platinum resistance thermometer (PRT) with excellent short-term repeatability and comes with an unaccredited NIST-traceable calibration. You won’t find another NIST-traceable reference temperature sensor that matches the accuracy and temperature range of the 5616 for the same price.
The temperature range of the 5616 covers –200°C - 420°C, and its high-purity platinum element and durability make it great for calibrating in the lab or in the field. When choosing a reference with a platinum element, there are two things you want to look at carefully: the short-term repeatability and the long-term drift. When PRTs are thermally cycled over their temperature range as they would be during a calibration, their resistance at the triple point of water can move up and down within an expected range. Fluke Calibration defines this range (called “short-term repeatability) as the repeatability at the triple point of water during three thermal cycles. 5616s are among the best performing in their class with short-term repeatability better than +/- 0.010°C (+/- 0.004°C is typical). In addition, the 5616’s drift is +/- 0.007°C at the triple point of water when exposed up to its maximum temperature (420°C) for 100 hours. These specifications are given at k = 2 and therefore include a 95 % confidence level.
The 5616’s sealed INCONEL® 600 sheath is 298 mm (11.75 in) long and 6.35 mm (0.250 in) in diameter. The probe’s PTFE-jacketed cable is made of silver plated copper that ends with four-wire leads, which eliminate the effects of lead-wire resistance on measurements. Use the 5616 with Fluke Calibration’s 1523/1524 Handheld Reference Thermometer, 1560 Black Stack, 1529 Chub-E4, or 1502A Tweener thermometer readouts.
Each sensor comes with a manufacturer’s report of calibration. The report includes the expanded uncertainty (k = 2) at seven calibration temperature points, ITS-90 calibration coefficients, and a temperature vs. resistance table presented in 1°C increments. Compare the 5616 to other Secondary Reference PRTs. You’ll like its price, but you’ll love its performance.
• Temperature range: –200°C - 420°C
• Excellent stability: +/- 10 mK
• Calibrated accuracy +/- 0.011°C at 0°C
• Reference-grade platinum sensing element
• NIST-traceable calibration included
Accessories
Fluke Calibration2601 Probe Carrying Care
Plastic probe carrying case for probes up to 228 mm (9 in) in length
Call today! Only available in Canada.