2567 Standard Platinum Resistance Thermometer Module, 1000 Ω

2-channel module reads 1000 Ω RTDs

Have questions? We're here to help!
Have questions? We're here to help!

For 1000 Ω PRTs, these modules provide all the same great features as the 2560 and 2562 Modules. The two-channel 2567 Module has a resistance range of 0 to 4000 Ω and is accurate to +/- 0.006°C at 0°C. The 2568 Module reads up to eight 1000 Ω PRTs and at 0°C is accurate to +/- 0.01°C. Don’t use an ohmmeter or multimeter to read your 1000 Ω PRTs when you can use a Black Stack loaded with convenient temperature functions.

The 1560 Black Stack is an incredible thermometer. You buy only the modules you need for the work you are doing. If your work changes, simply order the modules with the functions you need and slip them onto the back of the Stack. Your thermometer changes its software, display, and method of operation to match the new functions you’ve added.

Remember, you never have to open the case to add modules. There’s no software to load. It’s all automatic.

Each module stores its own calibration internally, so you can add or change modules without recalibrating the whole stack. Module calibration is digital and is performed manually through the base’s front panel or over the RS-232 link. If your lab has the capability, you can calibrate modules yourself. If not, send them to us with or without your base unit and we’ll recalibrate them.

The LCD screen has multiple methods of displaying data, including a graphical strip chart recorder. The graphical capability of the Black Stack makes testing temperature stability easier than ever. Vertical scaling and graph resolution are automatic.

The Stack has high-accuracy, two-channel capability or multi-channel functionality if you need it. Its memory stores the most recent 1000 readings, or you can send your data to your PC through the RS-232 port. Each data point is time and date stamped. An IEEE-488 port is optional.

With the Black Stack you can read data almost anyway you like—in ohms, millivolts, or temperature, according to your application and preference.

Remember, this thermometer’s calibration is traceable to NIST. Its accuracy is as high as ±0.0013°C, depending on the module and sensor you’re using.

Input Channels2
Resistance Range0 Ω to 4 kΩ
Basic Resistance Accuracy+/- 25 ppm of reading (0.025 at 1 kΩ)
Resistance Resolution0.001 Ω
Temp. Range–260°C - 962°C
Equivalent Temperature Accuracy+/- 0.006°C at 0°C
+/- 0.009°C at 100°C
Temp. Resolution0.0001°C
Excitation Current0.1 mA, 0.05 mA

Request a Calibration Quote

We’re here to make calibration easy. Request a quote today and let our team give you the care, precision, and service you can trust.