200M Meteorological System

No drift/hysteresis, no sensor calibration required, self-diagnostics and continuous unattended operation

Starting at
$9,950.00USD
Have questions? We're here to help!
Have questions? We're here to help!
Configure

The Model 200M is a complete instrument for the measurement of Atmospheric Dew Point, Ambient Temperature, % Relative Humidity, or other Psychrometric Variables. It employs the very reliable optical chilled mirror sensing technique which provides a primary measurement of dew point, and is traceable to NIST. The Model 200M is ideally suited for installations requiring continuous, automatic, and unattended measurement of humidity over a very wide range. 

 
Automatic Balance Control (ABC) cycle corrects the light reducing effects of mirror contaminants and allows for continuous monitoring and virtually maintenance-free operation. This is the first and only chilled mirror technology that truly reduces the need for cleaning by the incorporation of self-diagnostics, which indicates to the user, locally via an LED light source and remotely via logic level TTL signal, when and if maintenance is required.

• Primary measurement technique
• High accuracy and reliability
• Certificate of Traceability to NIST provided
• Sensing scheme discriminates between dew and contamination
• Reduces maintenance requirements
• No drift, no hysteresis
• Fast response
• No sensor calibration required
• Self-diagnostics and continuous unattended operation. No balancing or other adjustments required
• Chilled mirror sensor selection required

Range:
Dew Point:-23 to 50ºC (-10 to 122ºF) D1
-50 to 50ºC (-58 to 122ºF) D2
Ambienet Temperature:-50 to 50ºC (-58 to 122ºF)
% Relative Humidity:Approximately 5% to 95%, D1 (Equivalent Range)
Approximately 1% to 95%, D2
Accuracy:
Dew Point and AT:±0.25ºC (0.5ºF)
% Relative Humidity:±1.0 to 1.5%
Dew Point Depressions:45ºC (81ºF), D1
65º (117ºF), D2
Temperature Sensors:PRT (Platinum Resistance Thermometer), 100 ohms at 0ºC
Output(s):0-5 VDC or 4-20mA over span (DP) TTL compatible clean mirror signal
Power:90-260 1 VAC, 50-400 Hz, 40 watts maximum. RFI and Line Surge Protection provided.
Sensor:D1, D2 are one- and two-stage dew point (DP) sensors
Selection:AT is an Ambient Temperature sensor
• Aeronautics
• Atmospheric Sciences
• Government Agencies