1595A Super-Thermometers

Combine the accuracy of complex & expensive bridges w/ innovative features that simplify measurement processes & provide excellent value

Have questions? We're here to help!
Have questions? We're here to help!

The Fluke Calibration 1594A and 1595A Super-Thermometers combine the accuracy of complex and expensive bridges with innovative features that simplify measurement processes and provide excellent value. They are accurate enough for the primary lab and economical enough for the secondary lab. With temperature-controlled internal reference resistors, six input channels, a large graphical display, and a multitude of temperature-specific measurement functions, PRT, thermistor and SPRT calibration (0 Ω - 500 kΩ) has never been so easy and economical. And with the built-in Ratio Self-Calibration function, you can verify or calibrate the Super-Thermometer’s ratio accuracy in-house with the press of a button—no other single thermometry bridge can do so much, so well!

• Calibrate SPRTs, PRTs, RTDs and thermistors (0 Ω - 500 kΩ)
• Accuracy as good as 0.06 ppm (0.000015°C)
• “Ratio Self-Calibration” verifies and calibrates resistance ratio accuracy
• Automatic zero-power measurements calculate thermometer probe self-heating
• Temperature-controlled internal reference resistors
• Calibrated sensing current lowers overall instrument uncertainty
• Four input channels on the front panel accept sensors under test or external references
• Two dedicated external reference input channels on the rear panel
• Standby current reduces transient effects when scanning between channels
• Channel Select keys turn measurement mode on or off at the touch of a button
• Sample rates as fast as one second
• USB data transfer and computer control
• Remote view and device control via Ethernet
• Compatible with MET/TEMP II automated calibration software and LogWare II multichannel, real-time data acquisition software
• Includes NVLAP-accredited certificate of calibration, User’s guide, Technical guide (English only on CD-ROM), RS-232 to USB converter cable, and regional power cord

Measurement Capability4-wire PRT, Thermistor, Resistance, Resistance Ratio
Input Resistance Range0 - 500 kΩ
Ratio Range0 - 10
Accepted External RS Range1 Ω - 10 kΩ
Internal RS1 Ω, 10 Ω, 25 Ω, 100 Ω, and 10 kΩ
PRT Conversion TypesITS-90, PT-100, CVD-ABC, CVD-ALPHA, Polynomial
Thermistor Conversion TypesR(T) Polynomial, T(R) Polynomial
Display Unitsratio (RX / RS), K, °C, °F, Ω
Display Resolution0.1 - 0.000001
Sample Period (Seconds)[1]1, 2, 5, and 10
StatisticsAverage, Std Dev, SE of Mean, Max, Min, Difference, Peak-Peak, Delta, N
Front Panel ChannelsFour PRT/Thermistor inputs (channels 2 & 4 can be configured for either RX or RS inputs)
Rear Panel ChannelsTwo dedicated reference resistor inputs (RS)
Input TerminalsDWF Connector, Tellurium Copper
Data Logging to Internal Memory80,000 individual time- and date-stamped readings (~6 MB)
Internal Real-Time lockYes
CommunicationsRS-232, USB, IEEE-488, Ethernet
Display TypeFull VGA, LCD
User Interface Languages English, French, Spanish, German, Russian, Chinese, Japanese
[1]Two second sample rate required for full accuracy
  • Thumbnail of document Fluke 1594 1595 User Manual 2318
    Download

    Fluke 1594 1595 User Manual 2318

    Download
  • Thumbnail of document Fluke 1594 1595 Data Sheet 2319
    Download

    Fluke 1594 1595 Data Sheet 2319

    Download

Accessories

Request a Service Quote

Get a customized quote for calibration, validation, repair, or training services designed to keep your instruments accurate and compliant.
Learn more

Browse By Brands

Uncover the brands that set the standard for quality and dependability in every industry we serve.
Learn more