Skip to main content
Press Enter
Thunder Scientific

1220 Automated "Two-Pressure" Humidity Generation System

A self-contained system capable of producing atmospheres of known humidity using the fundamental “two-pressure” principle

Have questions? We're here to help!
Have questions? We're here to help!

 The 1220 Humidity Generation System is a self-contained system capable of producing atmospheres of known humidity using the fundamental “two-pressure” principle. This system is capable of continuously supplying relative humidity, dew point, frost point, parts per million, or other calculated values for instrument calibration and evaluation as well as for precision environmental testing. This system will automatically generate manually entered humidity and temperature set points as well as user created multipoint profiles. All desired humidity’s, temperatures, flow rates, and time intervals may be programmed. The 1220 humidity generating system incorporates a test chamber, with internal dimensions of 8” x 8” x 8”. Test chamber pressure range is ambient. Access is available through one 1.875” diameter port located on the right side, for probes, cables, sample tubes. The test chamber accommodates various solid-state sensors, sensing systems, chilled-mirror hygrometers, as well as material samples for environmental testing. Virtually any humidity and temperature may be generated, for long periods of time, within the operational limits of the generator. The output or recording of the device under test may then be compared with the generator’s data for analysis.

• Traceable to SI 1
• 0.6% of Reading RH Uncertainty 6
• No Refrigerants - Thermoelectric Cooling/Heating
• Based on NIST Proven "Two-Pressure" Principle
• ControLog Embedded Automation Software
• Automatically Applies Enhancement Factors
• HumiCalc with Uncertainty Mathematical Engine
• Generate: RH, DP, FP, PPM, Multipoint Profiles
• Test Chamber 8" x 8" x 8"
• Flow Capability of 20 L/min
• Multi-point Touch Display
• Window Door Option Available
Relative Humidity Range: 10 to 95 %RH, 1 to 20 L/min
Relative Humidity Range: 95 to 98 %RH, 1 to 10 L/min
Frost Point Temperature Range: –22.0 to 0 °C
Dew Point Temperature Range: –24.5 to 59 °C
Chamber Fluid Temperature Range: 2 5 to 60 °C
Chamber Fluid Temperature Control Stability: 3 0.002 °C
Chamber Temperature Uniformity: 4 0.05 °C
Chamber Fluid Temperature Heating/Cooling Rate: 0.3 °C per Minute (average)
Gas Type: Air or Nitrogen
Dew Point Uncertainty: 0.08 °C
Dew/Frost Point Uncertainty: < 0 °C 0.05 °C
RH Uncertainty: 95 to 98 %RH, ±10 °C of Ambient, @ 10 L/min 0.6% of reading
RH Uncertainty: 10 to 95 %RH, 5 to 60 °C, @ 20 L/min 0.6% of reading
UNCERTAINTY 5 & 6
Weight: (Generator Only) 150 lbs (68 kg)
Physical Dimensions: 16.1" H x 27.9" W x 19.2" D (409 mm x 708 mm x 487 mm)
Access Port: Ø1.875" (47.6 mm) located on right side
Test Chamber Dimensions: 8" x 8" x 8" (203 mm x 203 mm x 203 mm)
Display Resolution: 0.001
Test Chamber Pressure Range: Ambient
Saturation Pressure Specification: 0.02% of full scale
Saturation Pressure Range: Ambient to 160 psiA
Gas Flow Rate Specification: 5% of full scale
Gas Flow Rate Range: 1 to 20 L/min
Gas Pressure Rating: (MAWP) 175 psiG
Humidity: 5 to 95% Non-condensing
Storage Temperature: 10 to 50 ºC
Operating Temperature: 15 to 30 ºC
ENVIRONMENTAL
Gas Supply (External): 175 psiG @ 20 L/min
Electrical Power: 100-240 V~, 5 A, 50/60 Hz
UTILITIES
Test Chamber Pressure Uncertainty: Ambient 0.007 psiA
Temperature Uncertainty: 5 to 60 °C 0.031 °C
  • Thumbnail of document 1220 System Specs 2024 06 18533
    Download

    1220 System Specs 2024 06 18533

    Download

Request a Service Quote

Get a customized quote for calibration, validation, repair, or training services designed to keep your instruments accurate and compliant.
Learn more

Browse By Brands

Uncover the brands that set the standard for quality and dependability in every industry we serve.
Learn more